Operation Manual

Gas
09-1
Chapter 9: Gas
9.1 General safety rules when using LPG
ttings
If you suspect that gas is leaking, take the following
measures immediately:
• Close the stop valve on the gas cylinder.
• Ignition sources such as open ames or smoking are
strictly forbidden.
• Air the rooms.
• Clear the danger zone.
• Inform your immediate surroundings (groundsman)
and, if necessary, the re brigade.
The gas ttings may only be taken into operation again
after they have been checked by an expert.
Built-in objects and changes
• Objects may only be built in and changes to the gas t-
tings made by an expert.
• Only devices with a constant connection pressure of 30
mbar may be operated.
• Following any changes to the gas ttings they must be
rechecked by a recognised expert, who must provide a
written conrmation.
Checkingthegasttings
• Before initial operation have the LPG ttings checked by
an expert.
• The gas ttings must be checked every 2 years by an LPG
expert. This must be conrmed on the certicate (in ac-
cordance with Form G 607 from the German Association
of Gas and Water Experts (DVGW) and EN 1949).
• The regulator and waste gas pipes must also be checked.
• We recommend that you replace the safety regulator at
least every 6 years.
• The connecting hose should also be checked regularly for
damage. Replace it immediately if you nd tears, porous
spots or similar damage.
• The operator is responsible for having checks carried out.
You are not permitted to operate the heating system while
driving!
Exception:
As an optional feature, the vehicle can be equipped with a
gas pressure regulator for use while driving (e.g. Control CS,
SecuMotion).