Operation Manual

Gas
09-1
Chapter 9: Gas
9.1 General safety rules when using LPG
ttings
If you suspect that gas is leaking, take the following
measures immediately:
Close the stop valve on the gas cylinder.
Ignition sources such as open ames or smoking are
strictly forbidden.
Air the rooms.
Clear the danger zone.
Inform your immediate surroundings (groundsman)
and, if necessary, the re brigade.
The gas ttings may only be taken into operation again
after they have been checked by an expert.
Built-in objects and changes
Objects may only be built in and changes to the gas t-
tings made by an expert.
Only devices with a constant connection pressure of 30
mbar may be operated.
Following any changes to the gas ttings they must be
rechecked by a recognised expert, who must provide a
written conrmation.
Checkingthegasttings
Before initial operation have the LPG ttings checked by
an expert.
The gas ttings must be checked every 2 years by an LPG
expert. This must be conrmed on the certicate (in ac-
cordance with Form G 607 from the German Association
of Gas and Water Experts (DVGW) and EN 1949).
The regulator and waste gas pipes must also be checked.
We recommend that you replace the safety regulator at
least every 6 years.
The connecting hose should also be checked regularly for
damage. Replace it immediately if you nd tears, porous
spots or similar damage.
The operator is responsible for having checks carried out.
You are not permitted to operate the heating system while
driving!
Exception:
As an optional feature, the vehicle can be equipped with a
gas pressure regulator for use while driving (e.g. Control CS,
SecuMotion).