Operation Manual

8. Water
81
Emptying the water system
Use the control panel to switch o the electricity for the water
pump
o
by pressing the main switch for a longer period of time
(3 - 4 seconds).
Open all of the water taps
p
to the centre setting.
Hang up the adjustable shower head in the shower.
Open the outlet valves
q
on the therme (The therme is located
by the queen-sized bed/seating arrangement.).
Unscrew the cap on the cleaning port of the fresh water tank
j
.
Unscrew the overow pipe
l
in the fresh water tank.
Remove the lid of the water tank. Take out the water pump and
hold it up until the water pipes have emptied completely.
Check whether the tank, therme, faucets and pipes have emp-
tied completely. If necessary, blow out any remaining water in
the pipes using compressed air (max. 0.5 bar).
Re-insert the overow pipe and the water pump in the fresh
water tank and close the openings.
Leave the faucets
p
and the outlet valves
q
open.
Clean the tanks and rinse them thoroughly.
Allow the water system to dry for as long as possible.
Do not forget to empty the toilet cassette.
8
Diagram of hot water supply
7
6
8
If the vehicle is not being used and there is a danger of
sub-zero temperatures be sure to drain the entire wa-
ter system. Leave taps turn on in the middle position.
Leave all drain valves open.
Only empty your waste water tank at the special-
ly designated disposal points and never in open
spaces! As a rule disposal points can be found at
motorway service stations; campsites and petrol
stations.
1
Alde outlet valve
If an Alde hot water heater has been installed, the water
runs o through an outlet value
j
on the hot water
heater instead of through the therme (see also 10.5).
Outlet valves for therme
Alde outlet valve