Operation Manual
07-14
Setting the battery type
To reach this part of the menu, go to the "Loa-
ding the Battery" menu and press the button for
approx. 2 seconds.
The rst time it is used, the battery must be set
once to the type being used.
Recognising regulators (IBS-guided)
1. standard regulator
2. power control unit
If CI bus compatible chargers have been in-
stalled and are in operation, the operating states
of the charging units will be shown on the dis-
play by turning the rotary encoder. Up to two
charging units can be displayed.
No settings can be made in this menu.
Battery is charged:
Charging current: 7A
Expected recharging time: 4.5 h
Charge level: 60%
Battery charge
Battery is discharged:
Current drain: 5A
Remaining time until discharge: 8 h
Charge level: 50%
If the charge level indicator does not show a value,
the IBS must be recalibrated.Normally, the system
does this automatically. Neither the charging nor
the discharge current may be more than 150mA
while the sensor is calibrating itself.
The system can be manually calibrated
- while using the 230 V mains operation or
- if no electrical device has been switched on in
12 V operation.
To do this, the 30A main fuse must be switched off
on the battery container by pressing the button.
Now the sensor can calibrate itself. This process
takes approx. three hours. If the fuse is then swit-
ched on again, the % will be shown on the display.