Operation Manual

09-6
If the ame extinguishes again, re-ignition
takes place during the closing phase of the
fusible cut-out of the ignition safety switch
(approx. 30 seconds).
If no ame is ignited, the automatic ignitor
(2) will continue to work until the operation
handle (1) is switched to “0”.
To shut off:
Turn the operation handle (1) to position "0".
The automatic ignitor is thereby shut off.
Close the bottle valve and the quick-close
valve if the unit is not used for a longer period
of time.
Changing batteries on the automatic igni-
tor:
If you cannot hear any ignition sparks or only
hear them in intervals of more than one second,
then you must insert a new battery.
Ensure that the heating has been switched
off.
Remove the radiator cover (see Truma opera-
ting instructions).
Push the cover of the battery compartment
up and exchange the battery (take special
note of plus and minus).
Close the battery compartment.
Use only a temperature-resistant (+70° C) and
leakproof mignon battery.
Insert new batteries before the begin-
ning of each heating season..
Also note the separate operating in-
structions from the manufacturer.
2
1