Operation Manual
10-8
Rules for the exterior structure:
• Turn stanchions down; afterwards, relieve
pressure on wheels and axles.
• Preserve painted exterior surfaces with a suit-
able material.
• Treat the metal parts of the undercarriage with
a wax-based anti-rust agent.
• Cover with tarpaulins, ensuring that ventila-
tion is not obstructed.
• Leave the forced ventilation system open.
• Air the camper thoroughly every three to four
weeks.
Rules for containers:
• Empty and clean the fresh water tank with a
pump, if necessary with a plunger.
• Empty and clean the waste water tank.
• Empty and clean the WC tank.
• Empty the warm water boiler completely.
Turn the switch of the fresh water pump in the
on-board control center to "OFF" and open all
faucets.
• Ensure that no water can seep into the forced
ventilation system in the oor and into the
heating element.
also note the guidelines and opera-
ting instructions from the manufac-
turers of all built-in devices.