INSTALLATION
Immediately after unpacking the oven, check for possible shipping damage. If the 
oven is found to be damaged, save the packaging material and contact the carrier 
within 15 days of delivery.
Prior to installation, test the electrical service to make sure that it agrees with the 
specications on the machine data plate located at the lower outside corner of the 
oven. 
LOCATION
The oven must be installed on a level surface within 5 feet of both an open drain 
and a hot water supply.  The installation location must allow adequate clearances 
for servicing and for proper operation.  Suitable space is needed for the grease 
container and the chemical cleaner supply bottle and for access at the doors. For 
stacked and countertop congurations, the minimum clearance on the right side 
for plumbing and electrical connections is 3".  For out-of-sight, drop-through utility 
connection into the stand accessory, 0" clearance is required on all sides. Wood 
laminates, veneers, etc. are unsuitable materials for use in areas exposed to self-
cleaning oven, steam  and  detergents. The rotary oven must not be installed in 
high-moisture environments such as meat rooms or where high pressure cleaning 
is used. 
LEGS, CASTERS OR STAND ACCESSORIES
A set of four 4" tall legs is available as an accessory.  Casters are included with the 
stacking kit accessory. An oven stand accessory is available; the oven is mounted 
on top of the stand. 
Tethering is required for units equipped with casters, either on a stand or stacked.  
Refer  to the  Stand  or  Stacking  Kit  Instructions  for  additional  installation 
information.
CONNECTION INFORMATION — GENERAL
Machine comes standard with utility connections on the right 
side (Figs. 1 & 2). 
For out-of-sight, drop-through utility connection into the stand 
accessory, contact Hobart Service.  A drop-through utilities 
relocation kit is included with the stand accessory.
Legend (Fig. 1)
E1 Electrical, page 7.
P1 Water Drain, page 5.
P2 Chemical Supply, page 6.
P3 Grease Drain, page 6.
P4 Hot Water Supply, page 5.
Fig. 1
E1
P1
P4
P3
P2