GAS FRYERS WITH OR WITHOUT FILTER-IN-A-DRAWER Instructions Manual MODELS HGF35 ML-126994 HGF45 ML-126995 HGF65 ML-126996 HGF85 ML-126997 HGFD35 ML-126416 HGFD45 ML-126417 HGFD65 ML-126418 HGFD85 ML-126419 HGFC35 ML-126420 HGFC45 ML-126421 HGFC65 ML-126422 HGFC85 ML-126423 HGFD45 FORM 35614 (February 2004) HGF35F ML-135536 HGF45F ML-135537 HGF65F ML-135538 HGF85F ML-135539 HGD35F ML-126953 HGD45F ML-126956 HGD65F ML-126959 HGD85F ML-126962 HGC35F ML-126954 HGC45F ML-126957 HGC65F ML-126960 HGC85F ML-1
– 36 –
FORM 35614 (February 2004) PRINTED IN U.S.A.
ALARMS AND ERROR MESSAGES (HGD and HGC Series)
Pilot Out - If the pilot is out, the control displays the following message: (Electronic ignition only)
HGD Series - FIrE OUt
HGC Series - PILOT OUT
If no action is taken after 90 seconds, an alarm sounds continuously, the heat demand is disabled and
any running cooking cycles are cancelled. The control displays the following message:
HGD Series - Ign LoC
HGC Series - IGNITION LOCKOUT
The fryer must be turned off, then back on before the pilot can be relit and normal fryer functions
resumed. See pages 14 and/or 15 for lighting instructions pertaining to your particular model.
Open Probe - If an open probe is detected, the heat demand is disabled and any running cooking cycles
are cancelled. All operator buttons are disabled. The control displays the following message:
HGD Series - Prob
HGC Series - OPEN PROBE
The alarm sounds continuously until the fault clears or the fryer is turned off, then back on. If the problem
persists, call service.
Shorted Probe - If a shorted probe is detected, the heat demand is disabled and any running cooking
cycles are cancelled. All operator buttons are disabled. The control displays the following message:
HGD Series - Hi
HGC Series - SHORTED PROBE
The alarm sounds continuously until the fault clears or the fryer is turned off, then back on. If the problem
persists, call service.
Hi Temperature - If the temperature is greater than or equal to 415°F (212°C), the heat demand is
disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control
displays the following message:
HGD Series - Hi
HGC Series - SHORTED PROBE
The alarm sounds continuously until the fault clears or the fryer is turned off, then back on. Normal fryer
operations resumes when temperature drops below 415°F (212°C). If the problem persists, call
service.