GAS FRYERS WITH OR WITHOUT FILTER-IN-A-DRAWER Instructions Manual MODELS HGF35 ML-126994 HGF45 ML-126995 HGF65 ML-126996 HGF85 ML-126997 HGFD35 ML-126416 HGFD45 ML-126417 HGFD65 ML-126418 HGFD85 ML-126419 HGFC35 ML-126420 HGFC45 ML-126421 HGFC65 ML-126422 HGFC85 ML-126423 HGFD45 FORM 35614 (February 2004) HGF35F ML-135536 HGF45F ML-135537 HGF65F ML-135538 HGF85F ML-135539 HGD35F ML-126953 HGD45F ML-126956 HGD65F ML-126959 HGD85F ML-126962 HGC35F ML-126954 HGC45F ML-126957 HGC65F ML-126960 HGC85F ML-1

– 33 –
CLEANING
WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING,
CLEANING AND SERVICING THE FRYER.
DAILY
Clean all exterior surfaces of your fryer at least once daily.
Use a damp cloth with warm water and a mild soap or detergent.
Rinse thoroughly, then polish with a soft, dry cloth.
Keep the fryer exterior clean and free of accumulated grease to prevent stubborn stains from
forming. If regular cleaning is neglected, grease will be burned on and discolorations may form.
Remove discolorations by washing with any detergent or soap and water.
Use a self-soaping nonmetallic scouring pad for particularly stubborn discolorations.
Always rub with the grain of the stainless steel.
Do not use a scouring pad or harsh cleaners on the keypad or display area.
Cleaning instructions for fryers equipped with Filter-In-A-Drawer are covered in a separate
instruction manual. Follow the instructions accordingly.
WEEKLY OR AS REQUIRED
1. Drain shortening.
NOTE: Fryers equipped with Filter-In-A-Drawer are covered in a separate instruction manual.
Follow the instructions for draining the tank.
2. Flush out scraps and sediment with a small amount of warm shortening.
3. Allow the tank to drain thoroughly.
4. Close the drain valve and fill the tank with a noncorrosive, grease-dissolving commercial cleaner.
Follow the manufacturer’s instructions.
5. Boil the solution for 15 to 20 minutes. If the cleaner is a water-based chemical, temperature may
be 190°F to 212°F (88°C to 100°C). On HGF fryers, set the thermostat as low as possible. Follow
the manufacturer’s instructions. Monitor boiling to prevent overflow.
NOTE: HGFD and HGFC are equipped with the BOIL feature, fill the tank with water and
cleaner and press BOIL. Fryer will automatically set the boil temperature to 192°F.
6. Drain the cleaning solution from the tank.
NOTE: On fryers equipped with Filter-In-A-Drawer, do not drain cleaning solution into the
pump or filter system. See Filter-In-A-Drawer manual for information on cleaning.
7. Close the drain valve and refill the tank with water.
8. Add 1 cup (235 mL) of vinegar to neutralize alkaline left by the cleaner.
9. Bring the solution to a boil, do not allow to boil over, and let stand for a few minutes.