GAS FRYERS WITH OR WITHOUT FILTER-IN-A-DRAWER Instructions Manual MODELS HGF35 ML-126994 HGF45 ML-126995 HGF65 ML-126996 HGF85 ML-126997 HGFD35 ML-126416 HGFD45 ML-126417 HGFD65 ML-126418 HGFD85 ML-126419 HGFC35 ML-126420 HGFC45 ML-126421 HGFC65 ML-126422 HGFC85 ML-126423 HGFD45 FORM 35614 (February 2004) HGF35F ML-135536 HGF45F ML-135537 HGF65F ML-135538 HGF85F ML-135539 HGD35F ML-126953 HGD45F ML-126956 HGD65F ML-126959 HGD85F ML-126962 HGC35F ML-126954 HGC45F ML-126957 HGC65F ML-126960 HGC85F ML-1

– 22 –
PARAMETER STEPS LEFT DISPLAY RIGHT DISPLAY
Press SELECT OPTIONS
Press DEGREES F or C F or C
Press to select Fahrenheit or Celsius. DEGREES F or C F or C
Press when complete. PROGRAM
Press SELECT OPTIONS
Press SET PASS NEW PASS
Press to select NO PASS. NO PASS NEW PASS
Press when complete. PROGRAM
Press SELECT OPTIONS
Press SET PASS NEW PASS
Press to select PASS REQ. PASS REQ NEW PASS
Press and enter numeric code. CODE XXXX NEW PASS
Press when complete. PROGRAM
Press SELECT OPTIONS OPTIONS
Press VOLUME # BEEPER
Press to select volume. 1, 2 or 3 BEEPER
Press when complete. PROGRAM
Fahrenheit or
Celsius
No Password
Required
Password
Required
Beeper
Volume
PROGRAMMING
Temperature, time and other parameters must be set before operating. Follow the Program Guide to
configure the fryer to your particular operation.
Programming Guide
Press
to enter into the program mode, then follow the steps under each parameter to enter the
desired information. To exit the parameter and save changes, press
. To exit the program
completely, press
again.
NOTE: To use set back parameter, the computer must be programmed for basket lifts. Lifts are factory
programmed before shipment.