GAS FRYERS WITH OR WITHOUT FILTER-IN-A-DRAWER Instructions Manual MODELS HGF35 ML-126994 HGF45 ML-126995 HGF65 ML-126996 HGF85 ML-126997 HGFD35 ML-126416 HGFD45 ML-126417 HGFD65 ML-126418 HGFD85 ML-126419 HGFC35 ML-126420 HGFC45 ML-126421 HGFC65 ML-126422 HGFC85 ML-126423 HGFD45 FORM 35614 (February 2004) HGF35F ML-135536 HGF45F ML-135537 HGF65F ML-135538 HGF85F ML-135539 HGD35F ML-126953 HGD45F ML-126956 HGD65F ML-126959 HGD85F ML-126962 HGC35F ML-126954 HGC45F ML-126957 HGC65F ML-126960 HGC85F ML-1
– 18 –
PROGRAMMING
Temperature, time, energy source and other parameters must be set before operating. Once these
parameters are set, the fryer can be operated at the touch of a button.
Press
to enter the program mode and scroll through the parameters. If the Parameter Lock feature
is on, LoC is displayed in the window and program entry cannot be accessed. To access the program
mode while LoC is on, press
UP
UP
within 6 seconds of pressing . To turn the Parameter
Lock feature off, see Program Guide below.
Programming Guide
Once in the program mode, the parameters are displayed in the order listed below. To exit the program
and save changes, press and hold
for approximately 2 seconds.
UP
UP
UP
UP
UP
UP
UP
* = Default setting
*
*
*
PARAMETER SELECT DISPLAY SCROLL
Left Timer
Press or to enter time.
LED is lit above the left basket
icon. The time value is displayed
in window.
Press and
scroll to next
item.
Right Timer Press or to enter time.
LED is lit above the right basket
icon. The time value is displayed
in window.
Press and
scroll to next
item.
Set Temperature
Press or to enter
temperature.
The temperature value is
displayed in window.
Press and
scroll to next
item.
Offset
Calibration
For service only
00F
or
-00F
Press and
scroll to next
item.
Melt Options:
Liquid shortening
Solid shortening
No melt
Press or to select melt
option.
CY L (Liquid shortening)
or
CY S (Solid shortening)
or
CY O (No melt)
Press and
scroll to next
item.
Energy
Source
Press or to select
source of heat.
gAS
or
ELEC
Press and
scroll to next
item.
Parameter Lock
Press or to lock or
unlock program entry.
LoC (Unlock Parameter)
or
ULoC (Lock Parameter )
Press and
scroll to next
item.
Fahrenheit or
Celsius
Press or to
select Fahrenheit or Celsius.
F
or
C
Press and
scroll to next
item.