HG SERIES GAS FRYERS WITH OR WITHOUT FILTER-IN-A-DRAWER Instructions Manual MODELS HGFS25 ML-126410 HGS35F ML-126952 HGFS35 ML-126411 HGS45F ML-126955 HGFS45 ML-126412 HGS65F ML-126958 HGFS65 ML-126413 HGS85F ML-126961 HGFS85 ML-126414 HGD35F ML-126953 HGFD25 ML-126415 HGD45F ML-126956 HGFD35 ML-126416 HGD65F ML-126959 HGFD45 ML-126417 HGD85F ML-126962 HGFD65 ML-126418 HGC35F ML-126954 HGFD85 ML-126419 HGC45F ML-126957 HGFC35 ML-126420 HGC65F ML-126960 HGFC45 ML-126421 HGC85F ML-126963 HGFC65 ML-126

32
Battery Interplumbing (Available Only on Filter-In-A-Drawer Models)
A battery of fryers equipped with optional interplumbing connects the fry tanks to a common drain. Each
tank has an individual drain valve. Only one tank can be filtered at a time. Instructions for the Filter-In-
A-Drawer are covered in a separate manual. Follow the instructions accordingly.
Filtering Procedures (Non-Filter-Ready Fryers)
1. Shut down the fryer.
2. Slowly remove basket(s).
3. Open fryer door and attach the drain pipe to the drain valve.
4. Select a container that will hold all the liquified shortening and place it below the drain pipe.
5. If using a filter bag, tie it securely to the drain pipe. If a different filter medium is used, place it
in the container.
6. Open drain valve carefully so the oil stream is directed through the filter. See Filtering Guidelines
on page 31 for draining tips.
7. Flush out scraps and sediment in the fry tank with a small amount of warm shortening.
8. Drain the tank thoroughly and wipe clean.
9. Should it be necessary to clean the tank more thoroughly, see Cleaning on page 33.
10. Close the drain valve.
11. Pour the filtered shortening back into the fry tank.
12. Shortening level should be between the MIN and MAX lines.