HG SERIES GAS FRYERS WITH OR WITHOUT FILTER-IN-A-DRAWER Instructions Manual MODELS HGFS25 ML-126410 HGS35F ML-126952 HGFS35 ML-126411 HGS45F ML-126955 HGFS45 ML-126412 HGS65F ML-126958 HGFS65 ML-126413 HGS85F ML-126961 HGFS85 ML-126414 HGD35F ML-126953 HGFD25 ML-126415 HGD45F ML-126956 HGFD35 ML-126416 HGD65F ML-126959 HGFD45 ML-126417 HGD85F ML-126962 HGFD65 ML-126418 HGC35F ML-126954 HGFD85 ML-126419 HGC45F ML-126957 HGFC35 ML-126420 HGC65F ML-126960 HGFC45 ML-126421 HGC85F ML-126963 HGFC65 ML-126
– 20 –
USING THE FRYER (After Startup)
Models Without Basket Lift Option
1. Load the fry basket(s); do not overfill. See Recommended Basket Capacities on page 30.
2. Carefully lower basket(s) into shortening.
3. Press
to start the left timer. Press
to start the right timer.
4. When the timer times out, a beeper sounds. Press
silence the left timer beeper. Press
to silence the right timer beeper.
Models With Basket Lift Option
1. Place the fry basket(s) on the lift arm.
2. Load the fry basket(s); do not overfill.
3. Press
to lower the left basket. Press
to lower the right basket. The timer(s) begin
counting down.
4. When the timer times out, a beeper sounds and the basket(s) automatically raise. Press
to silence the left timer beeper. Press
to silence the right timer beeper.
SHUTDOWN
1. Press the power switch off.
2. For models equipped with a manual pilot, turn the gas valve extension arm to PILOT (the pilot
will continue to burn). To shut off all gas to the system, including the pilot, turn gas valve
extension arm to OFF.
3. For models with electronic igniter, turn the gas valve extension arm to OFF.
EXTENDED SHUTDOWN
1. Turn the main gas shutoff valve off.
2. Press the power switch off.
3. Unplug the fryer.
4. Turn the gas valve extension arm to OFF.
5. Drain the fryer.
6. Allow the fryer to cool, then apply a thin coat of cooking oil to tank interior and tank back to
prevent rust.