HG SERIES GAS FRYERS WITH OR WITHOUT FILTER-IN-A-DRAWER Instructions Manual MODELS HGFS25 ML-126410 HGS35F ML-126952 HGFS35 ML-126411 HGS45F ML-126955 HGFS45 ML-126412 HGS65F ML-126958 HGFS65 ML-126413 HGS85F ML-126961 HGFS85 ML-126414 HGD35F ML-126953 HGFD25 ML-126415 HGD45F ML-126956 HGFD35 ML-126416 HGD65F ML-126959 HGFD45 ML-126417 HGD85F ML-126962 HGFD65 ML-126418 HGC35F ML-126954 HGFD85 ML-126419 HGC45F ML-126957 HGFC35 ML-126420 HGC65F ML-126960 HGFC45 ML-126421 HGC85F ML-126963 HGFC65 ML-126
– 12 –
LEVELING FRYER
1. Place a spirit level on top of the fryer after gas connections have been made.
2. Adjust the legs to ensure that the fryer is level front-to-back and side-to side in the final installed
position.
FLUE CONNECTIONS
The fryer must be located under a hood with adequate connection to an exhaust duct. The hood must
extend 6" (15 cm) beyond fryer sides.
Adequate ventilation must be provided and comply with
Vapor Removal from Cooking Equipment,
ANSI-NFPA Standard #96 (latest edition), available from the National Fire Protection Association,
Batterymarch Park, Quincy, MA 02269.
Clearance above the fryer should be adequate for combustion byproducts to be removed efficiently. An
18" (46 cm) minimum clearance should be maintained between the flue vent and the filters of the hood
venting system. Never make flue connections directly to the fryer.
Do not obstruct the flow of the flue gases from the appliance. Proper air balance should be maintained
in the room.
ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE
NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL CODES.
WARNING: APPLIANCES EQUIPPED WITH ELECTRICAL SUPPLY CORD(S) ARE PROVIDED
WITH A THREE-PRONG GROUNDING PLUG, WHICH MUST BE CONNECTED TO A PROPERLY
GROUNDED RECEPTACLE. IF THE RECEPTACLE IS NOT THE PROPER GROUNDING TYPE,
CONTACT AN ELECTRICIAN. DO NOT REMOVE THE GROUNDING PRONG FROM THE PLUG.
Some fryers (depending on options) are equipped with a 120 V, 60 Hz, 1-phase cord and plug.
Do not connect fryer to electrical supply until after gas connections have been made.