HG SERIES GAS FRYERS WITH OR WITHOUT FILTER-IN-A-DRAWER Instructions Manual MODELS HGFS25 ML-126410 HGS35F ML-126952 HGFS35 ML-126411 HGS45F ML-126955 HGFS45 ML-126412 HGS65F ML-126958 HGFS65 ML-126413 HGS85F ML-126961 HGFS85 ML-126414 HGD35F ML-126953 HGFD25 ML-126415 HGD45F ML-126956 HGFD35 ML-126416 HGD65F ML-126959 HGFD45 ML-126417 HGD85F ML-126962 HGFD65 ML-126418 HGC35F ML-126954 HGFD85 ML-126419 HGC45F ML-126957 HGFC35 ML-126420 HGC65F ML-126960 HGFC45 ML-126421 HGC85F ML-126963 HGFC65 ML-126

11
GAS CONNECTIONS
CAUTION: ALL GAS SUPPLY CONNECTIONS AND ANY PIPE JOINT COMPOUND MUST BE
RESISTANT TO THE ACTION OF PROPANE GASES.
The gas inlet is located on the lower right rear of the fryer. Codes require that a gas shutoff valve be
installed in the gas line ahead of the fryer.
The gas supply line must be at least the equivalent of
1
/2" iron pipe for single units and 1
1
/4" for batteries.
If using the optional quick-disconnect flex hose;
3
/4" iron pipe for single units, 1
1
/4" iron pipe for batteries.
Make sure the pipes are clean and free of obstructions, dirt and piping compound. A battery requires
one or two connections of appropriate size and type for the gas requirement.
WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS.
USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.
After piping has been checked for leaks, fully purge gas pipes to remove air.
GAS PRESSURES AND ORIFICES
The gas pressure should be set at 4" W.C. (Water Column) (1kPa) pressure for natural gas and 10"
W.C. (2.46 kPa) pressure for propane gas. If incoming pressure exceeds
1
/2 psig (3.45 kPa), an
additional pressure regulator must be installed.
TESTING THE GAS SUPPLY PIPING SYSTEM
When test pressures exceed
1
/2 psig (3.45 kPa), the fryer and its individual shutoff valve must be
disconnected from the gas supply piping system.
When test pressures are
1
/2 psig (3.45 kPa) or less, the fryer must be isolated from the gas supply piping
system by closing its individual shutoff valve.