User Guide
– 6 –
EMPTY STRAINER BASKETS DURING OPERATION AS NECESSARY
The Strainer Baskets must be emptied periodically during operation to prevent them from over lling, 
which would adversely affect dishwasher operation. STOP the machine and open the access doors; 
Strainer Baskets are immediately inside at the front of the tanks. 
On Dual Rinse machines (FT900D or FT900SD) the strainer pan is located inside the machine behind 
the control box area. Remove and clean the strainer pan periodically.
LOADING
Pre-scrap dishes thoroughly to remove large food particles and debris. Never use steel wool  
on ware to be loaded into the dishwashing machine; this could introduce surface corrosion 
which could eventually interfere with machine operation.
All plates, saucers, trays, etc. should be loaded on the conveyor in an inclined position. Bowls should  
be loaded upside down. Silverware must be washed in racks to prevent loss of items unless the  
optional silverware conveyor is used; failing to do so could cause the conveyor to jam and damage 
ware or machine components. 
DO NOT attempt to wash large items (pots, pans, trays, etc.) without rst checking to make sure they 
will t through the machine opening. Such items must not be washed in this dishwasher unless they 
will easily pass through it.
Do not allow foreign objects to enter the unit, especially metallic contaminants.
UNLOADING
Remove dishes from the conveyor. If a dish  
pushes against the conveyor trip arm (Fig. 12),  
the conveyor stops and the pumps run for one 
minute before shuting off. 
Unload the conveyor starting with the ware  
furthest from the trip arm. Remove the dish  
that is striking the trip arm last. The machine 
automatically restarts.
RECOMMENDED MINIMUM TEMPERATURES 
The water temperatures in the tanks and rinse arms are monitored electronically and are displayed 
on the control box keypad display. The display should be checked periodically to assure that proper 
temperatures are being maintained. 
NOTE: Refer to the HOT WATER SANITIZING label on the right side of the control box for minimum 
temperature ratings.
Fig. 12
TRIP ARM 