TANK FILLING
Assure proper water hardness. Recommended water hardness is 3 grains or less per gallon. Higher 
hardness may cause excessive formation of lime scale. Chlorides must not exceed 50 ppm.
All water (and steam, if equipped) supply valves must be opened and the electric supply turned on before 
the machine will function.
Close all drains and doors. The drain handles are located near the oor at the front of each tank. Rotate 
drain handles clockwise to the vertical position. The prewash tank, powerwash tank and power rinse tank 
(when equipped) and their respective drain handles are located towards the load end of the machine from 
the control box. The drain handle for the dual rinse tank (when equipped) is located towards the unload 
end of the machine from the control box.
Press the Power key on the keypad located on the lid of the control box (Fig. 8). The display will light up.  
Fig. 8
If door(s) are not closed Door(s) Open displays. If all doors are closed, Tanks Filling ... displays and tanks  
begin to ll. All tanks will be full in approximately 10 to 15 minutes. NOTE: Opening a door during the 
ll cycle shuts off the ll valves (Door(s) Open displays). Close the door to resume the ll cycle (Tanks 
Filling ... displays).
When all tanks are full the ll valves will automatically shut off and the water temperatures display for  
each tank. The full time Auto-Fill feature adds water to the tanks to maintain proper water levels during 
operation.
After the water level raises the lower oat in each tank, the wash, rinse and dual rinse tanks, if equipped, 
begin to heat. If the water level drops below the lower oat in any tank, the heat shuts off and lling resumes 
on the affected tank(s). When the water level reaches the lower oat, heating resumes while the tank(s) 
continue(s) lling until the proper water level is reached. If the water level drops below the lower oat in 
the prewash tank, lling resumes until the water level reaches the upper oat.
NOTE: A red light is provided on machines with an electric Blower-
Dryer. The operator is alerted by the lighted red light (Fig. 9) that  
the over-temperature thermostat has been activated. If light stays on 
for more than 5 minutes, the operator should TURN THE MACHINE 
OFF, DISCONNECT POWER TO THE MACHINE, AND HAVE IT 
SERVICED BY A QUALIFIED SERVICE TECHNICIAN.
Fig. 9
Electric Blower-Dryer, does not 
have an ON / OFF Switch, but does 
have a Red Indicator Light
 If red indicator lights:
• Disconnect from power supply
• Have unit serviced by qualified
 technician