MAINTENANCE
Unplug the machine power cord and turn the index knob fully clockwise to
close the gauge plate before doing any maintenance on the slicer.
KNIFE SHARPENING
The CleanCut
TM
K NIFE will provide long service in normal food retail or commercial kitchen use. Sharpen
only when necessary; prolonged or too frequent sharpening results in unnecessary K
NIFE wear.
Remove the T
OP KNIFE COVER and the plastic RING GUARD COVER.
Turn the L
ATCH KNOB counterclockwise and lift the TOP KNIFE
COVER and plastic RING GUARD COVER off the slicer (Figs. 5, 6 & 7).
Thoroughly wash the area around the K
NIFE and both sides of the
outer rim of the K
NIFE. Food debris should not be allowed to
transfer from the K
NIFE to the SHARPENER. Plug in the machine
power cord. Press the K
NIFE ON button (Fig. 9 or Fig. 10) with
your right hand while pulling the S
HARPENER LEVER fully forward
with your left hand (Fig. 29). Sharpen for approximately
8 seconds. Release the S
HARPENER LEVER. Press the OFF button.
Unplug the SLICER power cord. Wipe the slicer with a clean damp
cloth to remove any grinding particles. Reinstall the plastic R
ING
GUARD COVER and the TOP KNIFE COVER.
LUBRICATION — Carriage Slide Rod
The slicer lubrication system requires that the reservoirs under the C
ARRIAGE TRANSPORT be refilled with
Lubriplate FMO-200-AW oil (supplied) after approximately one year of operation for a manual slicer
(model 3613) and after approximately six months of operation for an automatic slicer (model 3713).
Typical operation is estimated to be 3 hours of slicing per day. To check whether the reservoirs are
empty, lift up the front of the slicer base and allow the C
LEANING LEG to swing straight down; pull the
C
LEANING LEG all the way to the front (Fig. 18).
Remove the S
IDE PANEL (Fig. 7) (4 screws) and look
through the C
ARRIAGE SLOT (Fig. 7) to observe the
oil level in the C
LEAR PLASTIC RESERVOIRS under the
C
ARRIAGE TRANSPORT (Fig. 30). A flashlight (not
supplied) might be helpful. To replenish the oil
reservoirs, aim the telescoping tube on the
Lubriplate FMO-200-AW oil bottle at the R
ESERVOIR
FUNNELS above the FRONT and REAR BEARING BLOCKS.
Gently squeeze the sides of the bottle to add drops
slowly to the reservoir(s) (Fig. 30). Move the
C
ARRIAGE TRANSPORT as necessary to access the
front and rear R
ESERVOIR FUNNELS. The drops will
slowly feed into the C
LEAR PLASTIC RESERVOIRS.
Replace the S
IDE PANEL.
SERVICE
Contact your local Hobart-authorized service office for any repairs or adjustments needed on the slicer.
Fig. 30
Fig. 29
RESERVOIR
FUNNELS
REAR BEARING
BLOCK
FRONT BEARING
BLOCK
CARRIAGE
TRANSPORT
CLEAR PLASTIC
RESERVOIRS
SHARPENER LEVER