User Manual

9
although the Water spilled from the cyclinder.
2
The water level detector is
already electrolyzed by some
adulterants
2
5
The instrument doesn’t arise temperature or
pressure or the shell of the instrument with
electricity
1
The power supply don’t connect
well.
2
electric heating tube is broken.
6
Examine the power taps.
7
Repalce promptly
3
There is steam in the pressure gauge.
steam leakage between The connection
Tighten the connections.
4
The security valve take off ahead of the time when the
working pressure still not reach the designed
pressure.
Steam leakage from the security valve
or security valve broken
Repalce promptly
5
The indicator on the pressure gauge not move to arise
or to zero.
1 The copper pipe in the tail of the
pressure gauge screwed too tight.
2 The pressure gauge is broken.
1 Screw heavily the
connection of the pressure
gauge in the tail
2 Replace the pressure gauge.
6
There is an over pressure alarming when you
set up the instrument or even in the normal
pressure ranges.
1 The pressure control button
not adjust well.
2 The pressure control button
is broken.
1 Adjust the pressure
control button a bit: turn
up by anticlockwise rotation
and turn down by clockwise
rotation
2 Replace the pressure
control button.
7
The telephone number of Henan Zhuoxian Import & Export Trading Co., Ltd: +86-13598894736
After-sales services
Without violation of the Rules of storing and application,the instrument can be guaranteed for a whole year after leaving the factory. But
please take note that some easily damage parts are outside the range of the guarantee.for example: the electric heating tube,40A Solid state relay,the
water level detector.Please refer to the following details to make the Warranty card.
Certificate of Guarantee
Thank you for purchasing our product,we can assure that all the people in my factory always take a strict
attitude towards our quality control and management,the following can be guaranteed once the troubles occurs.
The name of the product: Electric pressurized steam sterilizer
Add: Room 104, Building No. 3, Jiatu Zhiye Building, 500m in the north from intersection of Lianhua Street