Digital Audio Power Amplifier Professional Audio Power Amplifier Installation and Operation Manual V 1.
Contents Chapter 1 Overview.................................................................................................................... 1 Chapter 2 Functions and indications .......................................................................................... 2 Chapter 3 Connection and operation.......................................................................................... 3 3.1 Input/Output .............................................................................................
Remark: All rights reserved for translation, reprint or reproduction Contents may change without prior announcement All technical specifications are guideline data and not guaranteed features TAIDEN Co., Ltd. is not responsible for any damage caused by improper use of this manual The equipment must be connected to earth! This product conforms to the rules of the European directive 2014/30/EU To protect your hearing, avoid high pressure level on earphones.
Important Safety Instructions 1. Read these instructions. 17. Do not place the equipment on any uneven or unstable 2. Keep these instructions. stand; original product package or appropriate package 3. Heed all warnings. should be used to avoid damage caused by strong 4. Follow all instructions. impacts during transportation. 5. The apparatus shall not be exposed to dripping or 18. Power supply cords: AC 100 V - 240 V 50/60 Hz splashing and that no objects filled with liquids, such as 19.
Important Safety Instructions The exclamation mark within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. WARNING: To reduce the risk of fire or electric shock, DO NOT expose units to rain or moisture. Attention: Installation should be performed by qualified service personnel only in accordance with the National Electrical or applicable local codes.
Installation & User Guide About this manual This manual is a comprehensive guide to the installation and operation of the TAIDEN Digital Audio Power Amplifier (PA). It includes the detailed description of the functions and interfaces of the PA, including connection, installation, and operation. The manual is divided into the following chapters: Chapter 1:Overview An introduction to the Digital Audio Power Amplifier.
Chapter 1 Overview Digital audio power amplifier (hereinafter referred to as "PA") adopts the high efficiency class D power amplifier and switching mode power supply technology, the efficiency under conventional conditions is more than 80%.
Chapter 2 Functions and indications Front panel of HPA-2016/02 Front panel of HPA-2016/04 Rear panel of HPA-2016/02 Rear panel of HPA-2016/04 Figure 2.1 Digital audio power amplifier indicator will turn to green. 1. Power switch Power on/off. 6. Power indicator The "Power" indicator turns to green when power 2. Gain control Gain is controlled by dB attenuation. With the on. minimum set, the signal is completely cut off. 7. Signal input Male XLRM socket. 3.
10. Mode Switch Gain switch: When the gain of PA is 1 Vrms, the input sensitivity is 1 Vrms; When the gain of PA is 0.7 Vrms, the input sensitivity is 0.7 Vrms; Mode switch: MONO (DIP switch: MONO): signal inputs from channel A and output from channel A&B; MONO: signal inputs from channel C and output from channel C&D; STEREO (DIP switch: STEREO): channel A&B&C&D works independently; BRIDGE (DIP switch: MONO): signal inputs from channel A/C and output from channel A/C; 11.
Chapter 3 Connection and operation 3.
3.3 MONO mode 3.4 Bridge mode Note: In the bridge mode, the DIP switch is set to MONO, the signal is input from the A/C channel, and output from the A/C, and the output terminal is connected to 1+ 2-; The constant voltage output setting is the same as the bridge output setting.
3.5 Operating instructions Please confirm before installation: which will form ground loop and cause oscillation; The power cord not connected to the power 4. Do not connect the output to the power supply, socket; battery or mains supply. Otherwise it may cause The power switch is off; an electric shock; Volume knob turned off (counterclockwise to 5. limit).
3.6 Troubleshooting The following table lists the main reasons for the abnormal work and treatment measures, as well as the circuit protection in each case.
Chapter 4 Specifications PA Rated power (EIAJ THD=1%,1 kHz) HPA-2016/02 HPA-2016/04 2×200 W (4 Ω / 6 Ω) 4×200 W (4 Ω / 6 Ω) 2×160 W (8 Ω) 4×160 W (8 Ω) 1×400 W (Bridge) 2×400 W (Bridge) 1×400 W (70 V Constant voltage) 2×400 W (70 V Constant voltage) 1×400 W (100 V Constant voltage) 2×400 W (100 V Constant voltage) Voltage gain (8 Ω, 1 kHz) 31.0 dB Rising slope (1 kHz, Bypass low-pass filter) 50 V/μs Input sensitivity (Rated power, 1 kHz) 1 Vrms,0.
TAIDEN INDUSTRIAL CO., LTD. 6/F, Block B, Future Plaza, 6060 Qiaoxiang Rd, Nanshan District, Shenzhen, China P.C.: 518053 Website: http://www.taiden.