User's Manual

Table Of Contents
Figure 6-36 Second partyline connection type menu
5) Select ‘OFF’ to disable partyline termination on the port. This will apply regardless of
the type of partyline connected to the port. For example if the partyline is connected
to an MS-702 master station with termination enabled the Base station termination
must be disabled.
6) The changes are saved and applied automatically five seconds after the last time the
setup/enter encoder was pressed or turned. The front-panel display flashes to
indicate that the changes are being saved and applied.
The Base station automatically sets the port’s termination, gain, and call signalling options for
the selected partyline type.
6.15.2 To configure the Noise Gate for a partyline port
The noisegate sets a cutoff level below which audio input is ignored in order to avoid
transmitting low levels of background noise. The noisegate can be set to a value in the range -
70dB to -10dB when enabled.
1) Select PORTS from the main menu, then select PLCHA or PLCHB from the
AVAILABLE AUDIO port menu which appears.
2) The port configuration menu is displayed. Scroll rightwards to display the second
page of the menu.
3) Select GATE. The Noise Gate menu is displayed.
Figure 6-37 Partyline noisegate menu
4) Scroll to the ‘STATE’ option and press the setup/enter encoder to display the
noisegate state menu.
Figure 6-38 Partyline noisegate options menu
62
FreeSpeak II User Guide