User's Guide
Table Of Contents
- 1 Introduction
- 2 Installing Arcadia Central Station
- 2.1 Front Panel Connectors, Controls and Indicators
- 2.2 Intercom Touchscreens
- 2.3 Rear Panel Connectors and Indicators
- 2.4 System Powering
- 2.5 Clear-Com Ethernet Cable Recommendations
- 2.6 Stage Announce and Program Feed
- 2.7 Set the Arcadia Central Station IP address
- 2.8 Save and Restore System Configuration
- 2.9 Reset to Default
- 2.10 Example Applications
- 3 Connecting to other systems
- 4 Network Setup
- 5 Core Configuration Manager (CCM) walkthrough
- 6 CCM configuration
- 6.1 Setting up the Arcadia Central Station
- 6.2 Adding IP Transceivers (FS Edge, FS II 1.9, 2.4)
- 6.3 Registering beltpacks
- 6.4 Viewing and adding Channels
- 6.5 Viewing and Adding Members to Groups
- 6.6 Channels or Groups?
- 6.7 Creating and Editing Roles
- 6.8 Set up GPIOs and Logic Events
- 6.9 Monitoring Your System from the CCM
- 7 Security
- 8 Configuring from the Front Panel
- 9 Spare parts
- 10 Terminology/glossary
- 11 Front Panel Menu Reference Tables
- 12 Specifications
- 13 Pinouts
- 14 Regulatory compliance
User Guide | Arcadia Central Station
1. Configure channels in the CCM
2. Add roles and configure the keys on the beltpacks
2.10.3 Using IP Transceivers with the Arcadia Central Station
This set up has a total of 6 FS Edge transceivers with 16 Beltpacks connected. The IP
transceivers are connected via a network that is configured for AES67 traffic. These are
configured using the CCM. There are four 2-wire partylines and a Dante network.
Note: The Dante network must be on a different VLAN or network from the IP transceivers.
Note: The AES67 network must be set up correctly for the IP transceivers in order to meet the needs
of Clear-Com IP transceivers for high levels of PTP accuracy.
See the AoIP Network Recommendations guide, available from the Clear-Com FSII Knowledge
Center.
Page 20