Discharge Current Setting
Toggle up (▲) once to enter the “DSCH
CURRENT
” screen. Toggle right (►) once and the amperage value
will begin ashing. Toggle up (▲) or down (▼) to change the
amperage value. Toggle right (►) once to set the amperage.
Discharge Voltage Setting (3.0-3.3v per cell)
Toggle up (▲) once to enter the “DSCH
VOLTAGE
” screen. Toggle right (►) once and the voltage value will
begin ashing. Toggle up (▲) or down (▼) to change the voltage
value. Toggle right (►) once to set the voltage. Refer to page 7 for
recommended discharge voltages.
Terminal Voltage Setting
(Use At Your Own Risk)
Toggle up (▲) once to enter the “TVC=YOUR RISK!” screen.
Toggle right (►) once and the voltage value will begin ashing.
Toggle up (▲) or down (▼) to change the voltage value. Toggle
right (►) once to set the voltage.
Temperature Cut-O
(when using optional temp sensor)
Toggle up (▲) once to enter the “TEM-
PERATURE CUT-OFF
” screen. Toggle right
(►) once and the temperature value will
begin ashing. Toggle up (▲) or down (▼)
to change the temperature value. Toggle
right (►) once to set the temperature. The temperature can be set
between 20ºC and 80ºC.
Toggle up (▲) once to enter the “
SAVE PROGRAM” screen. Toggle
right (►) once to save all of the settings previously entered.
BATTERY MEMORY cont.
DSCH CURRENT
2.2A
DSCH VOLTAGE
3.0V/CELL
TVC=YOUR RISK!
4.20V
TEMPERATURE
CUT-OFF 50C
SAVE PROGRAM
ENTER
[ BATT MEMORY 1]
LiPo 7.4V(2S)
BATTERY MEMORY cont.
LITHIUM BATTERY METER