Owner's manual
36
After selecting the correct battery type, if
the screen does not read “
CHARGE”, toggle
up (▲) or down (▼) to select the “
CHARGE“ mode.
Toggle right (►) once and the amp rate
value will begin ashing. Toggle up (▲) or
down (▼) to adjust the value to the desired rate. Follow the in-
structions provided with your battery when setting the amp rate.
The amp rate should be set to 1/10 of capacity.
Toggle right (►) once and the voltage rate
value will begin ashing. Toggle up (▲) or
down (▼) to set the voltage and number of cells.
Toggle and hold the joysick to the right (►) for three seconds to
begin charging.
Once charging has commenced, the
charger will display the following real-
time information: battery type, charging current, battery voltage,
charging time and charged capactiy.
Once charging is complete, the screen will read “
END:FINISHED”
and the charger will emit a chiming sound. Toggle left (◄) once
to stop charging. You may toggle left (◄) at any time during the
charging process to stop charging.
Pb CHARGE
0.1A 2.0V(1P)
Pb CHARGE
0.7A 2.0V(1P)
Pb CHARGE
0.7A 12.0V(6P)
Pb-6 0.4A 14.70V
CHG 003:10 00029
Pb CHARGE MODE (cont.)