Manual

7
Always refer to recommendations from your battery manufacturer for your
speci c battery type and size before initiating a charge or discharge process.
Do not attempt to disassemble or modify Lithium or Lead-Acid battery packs.
Discharging
The X1 discharging functions are for two speci c purposes:
Refreshing the capacity of a Nickel-based battery that has lost capacity over
time (NiMH or NiCd).
Reducing the voltage of a Lithium battery for safe storage.
LITHIUM CHEMISTRY BATTERY PACKS SHOULD ONLY BE DISCHARGED
TO THEIR MINIMUM SAFE VOLTAGE, NO LOWER. DEEP DISCHARGING A
LITHIUM CELL WILL DO PERMANENT DAMAGE. REFER TO THE STAN
DARD BATTERY PARAMETERS TABLE ON PAGE 6 OF THIS MANUAL FOR
MINIMUM DISCHARGE VOLTAGES.
LiPo Charge/Discharge Cycling
Lithium batteries are known to reach full capacity after a break-in period of
about 10 charge/discharge cycles. We do not recommend you use the X1 char-
ger to do this, normal use and recharging will achieve the same results. If you
wish to perform a Lithium break-in on the bench with the X1, discharging to
minimum acceptable voltages and performing a balance charge at 1C maxi-
mum rate is recommended. If you choose to break in your Lithium batteries
under normal use, charging at only 1C for the  rst ten cycles will help ensure
full performance and service life from your Lithium cells.
Warnings and Safety Notes
Warning