Instructions

25
DPC-11
UNIVERSAL PROGRAMMING INTERFACE
FOR HITEC PrOGRAMMABLE SERVOS
CAUTION – Program the Fail Safe
point after setting the end and center
points, otherwise it will change when you
make those adjustments.
WARNING
WARNING
To set the Fail Safe point first click on the Fail Safe
under Program section.
7. Fail Safe Position
By choosing to use the Fail Safe function you will need
to set a preprogrammed travel point that the servo
will travel to in the event the servo loses signal from
the receiver.
Next move your servo to the desired position by
using the “Manual” positioning adjustments.
Once you have your desired Fail Safe position, click on
the “FS-Position” button in the Fail Safe Test section
to set the fail safe position. Once it is set, click the
button again to exit the Fail Safe setup.
NOTE – Remember to “Write All” of
your settings to your servo before closing
the DPC-11 software and disconnecting
your servo. Failure to do so will result in
lost programming data.
WARNING
WARNING
HSB-9XXX Servo Programming cont.