Instructions
25
DPC-11
UNIVERSAL PROGRAMMING INTERFACE 
FOR HITEC PrOGRAMMABLE SERVOS
 CAUTION – Program the Fail Safe 
point after setting the end and center 
points, otherwise it will change when you 
make those adjustments.
WARNING
WARNING
To set the Fail Safe point first click on the Fail Safe 
under Program section.
7. Fail Safe Position 
By choosing to use the Fail Safe function you will need 
to set a preprogrammed travel point that the servo 
will travel to in the event the servo loses signal from 
the receiver. 
Next move your servo to the desired position by 
using the “Manual” positioning adjustments. 
Once you have your desired Fail Safe position, click on 
the “FS-Position” button in the Fail Safe Test section 
to set the fail safe position. Once it is set, click the 
button again to exit the Fail Safe setup. 
 NOTE – Remember to “Write All” of 
your settings to your servo before closing 
the DPC-11 software and disconnecting 
your servo. Failure to do so will result in 
lost programming data.
WARNING
WARNING
HSB-9XXX Servo Programming cont.