Instructions
22
DPC-11
UNIVERSAL PROGRAMMING INTERFACE 
FOR HITEC PrOGRAMMABLE SERVOS
 NOTE – The FAIL SAFE point must be set by the 
user in the programming section under. Setting the 
FAIL SAFE Point.
WARNING
WARNING
FAIL SAFE Test
Programming your Hitec Brushless 
Servos:
 NOTE – To make your changes 
permanent you must “write” the 
programming to the servo by clicking the 
WRITE ALL button. You can do this after 
each programming step or wait until you 
have finished all programming. 
WARNING
WARNING
This feature tests the user-programmed FAIL 
SAFE point of your servo. 
If not already, turn on the Fail Safe by clicking 
the “Fail_Safe” button under “Program” and click 
“FS_Start.” The servo will travel to its preset Fail 
Safe position. 
The following functions can be programmed into 
the HITEC BLDC servos using the DPC-11. It is 
recommended that you program your servos in 
the following order: 
1. Direction of Rotation
2. Travel Speed (Slower)
3. Dead Band Width
4. Soft Start Percentage
5. Center and End Points
6. FAIL SAFE, On or Off
1. Direction of Rotation 
Normal servo rotation based on 900 - 2100µs input 
signal is clockwise from left to right. You can change 
this to counterclockwise by clicking on the direction 
of travel button as shown. The direction is shown as 
CW for clockwise and CCW for counterclockwise. 
HSB-9XXX Servo Programming cont.