Manual
Dial Button
AUTO-Extreme
With this highlighted, press the Adjust Dial. This will select the Test 
Mode and show a ‘Pause’ indicator in the lower right of the screen. 
Pressing the Adjust Dial again will select ‘Play’ and the servo will 
start moving. The servo speed is adjusted by turning the Adjust Dial. 
Press the Adjust Dial to ‘Pause’ or the BACK button to switch to a 
dierent Auto Test Mode. 
AUTO-Sweep
With this highlighted, press the Adjust Dial. This will select the Test 
Mode and show a ‘Pause’ indicator in the lower right of the screen. 
Pressing the Adjust Dial again will select ‘Play’ and the servo will 
start moving. The cycle speed is adjusted by turning the Adjust Dial.
Press the Adjust Dial to ‘Pause’ or the BACK button to switch to a 
dierent Auto Test Mode. 
AUTO-Step
With this highlighted, press the Adjust Dial. This will select the Test 
Mode and show a ‘Pause’ indicator in the lower right of the screen. 
Pressing the Adjust Dial again will select ‘Play’ and the servo will 
start moving. The Step increments are adjusted by turning the Adjust 
Dial.
Press the Adjust Dial to ‘Pause’ or the BACK button to switch to a 
dierent Auto Test Mode.
AUTO-DB (Deadband)
Use the Adjust Dial to highlight AUTO-DB and press it to enter the 
menu. The Auto Test will check the servos Deadband. When in the 
menu, press the Adjust Dial to begin the Test. A ‘Play’ symbol will be 
displayed in the lower right screen. Turning the Adjust Dial will adjust 
the microsecond range. The jitter range is 0.25 microseconds to 
100.0 microseconds.
Press the BACK button to exit.
Dial Button
Dial Button
In this mode, all manufacturer’s servos can be tested for operation. 
To begin testing servos, plug a servo into the servo slot on the 
programmer and install the correct battery type in the battery slot. 
Move the select switch to the TEST position.
1.  Manual test 
Using the Adjust Dial, highlight Manual, and press then Adjust 
Dial to enter.
At this point it is possible to move the servo using the Pulse Dial. 
As the dial is turned the OUTPUT box will show the current position 
of the servo in microseconds.
Pressing the Adjust Dial will switch to STEP mode allowing much 
ner control. Use the Adjust Dial to adjust the microseconds. Press 
again to exit.
Press the BACK button to exit the menu.
1.  AUTO – E/S/S Test (Extreme, Sweep, Step) 
Use the Adjust Dial to highlight AUTO – E/S/S and press it to 
enter the menu. 
In the Auto Test menu, it is possible to switch between Extreme, 
Sweep, and Step modes by turning the Adjust Dial. Each mode will 
display a cycle count and how much time has passed during the 
test. Before a mode is selected, the Pulse Dial will move the servo 
manually.
Here’s a brief explanation of the dierent modes:
Extreme – Moves the servo through minimum, middle (neutral), 
and maximum endpoints. Speed of the total movement can be 
adjusted. If the movement is set faster than the servo is rated, 
then the servo will not be able to move to each end point before 
changing direction. The speed ranges from 0.1 second to 5.0 
second.
Sweep – Moves the servo through minimum and maximum 
endpoints at an adjustable speed. The speed of the Sweep is 
adjustable between 2.4 seconds/cycle to 120 seconds/cycle.
Step – Moves the servo through the minimum and maximum 
positions at an adjustable Pulse Step. The Step range is 0.25 
microseconds to 100.0 microseconds.
Dial Button
Test Mode
Dial Button
Dial Button
Main Servo Test Screen
Use the Adjust Dial to select the desired test function. Once the 
function is highlighted, press the Adjust Dial to enter.