AC DUAL BALANCE CHARGER INSTRUCTION MANUAL WARNING: THE CHARGING OF RC HOBBY BATTERIES CAN BE DANGEROUS. FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN THIS MANUAL MAY RESULT IN PROPERTY DAMAGE AND/OR LOSS OF LIFE.
Table of Contents Table of Contents: Introduction...................................................................................................................................03 Warning and Safety Notes......................................................................................................04 Product Layout.............................................................................................................................07 Input Functions...........................................
Introduction Congratulations on your choice of the RDX2 Mini charger from Hitec RCD. The RDX2 Mini is a highperformance, microprocessor-controlled charger with battery management capabilities that are suitable for use with most popular battery types. The RDX2 Mini also features integrated balancing for two-four cell, Lithium-Polymer (LiPo), Lithium-Ferrite (LiFe) and Lithium-Ion (Li-Ion), as well as the latest high voltage Lithium-Polymer (LiHV) batteries.
Warning and Safety Notes Warning 4 NEVER LEAVE THE CHARGER UNATTENDED WHILE IT IS CONNECTED TO ITS POWER SOURCE. IF ANY MALFUNCTION IS FOUND, TERMINATE THE PROCESS AT ONCE AND REFER TO THE OPERATION MANUAL. A A A The allowable AC input voltage is 100-240V AC. A This charger and the battery should be put on a heat-resistant, non-flammable and nonconductive surface. A Never place a charger on a car seat, carpet or similar surface. Keep all flammable, volatile materials away from the operating area.
Warning and Safety Notes Continued PLEASE BEAR IN MIND THE FOLLOWING POINTS BEFORE YOU COMMENCE CHARGING: • • • Did you select the appropriate program suitable for the type of battery you are charging? Did you set up the adequate current for charging? Have you checked the battery voltage? Lithium battery packs can be wired in parallel and/or in series, i.e. a 2-cell pack can be 3.7V (in parallel) or 7.4V (in series).
Warning and Safety Notes Continued Charging Before charging your batteries, it is critical that you determine the maximum allowable charge rate for your batteries. The RDX2 Mini is capable of charging at high rates that may not be suitable or safe for your particular batteries. For example, Lithium cells are typically safe to charge at 1C, or the total mAh÷1000. A 1200mAh battery would have a 1C charge rate of 1.2 amps. A 4200mAh battery would have a 1C charge rate of 4.2 amps.
Product Layout 3 2 1 1. RDX 2 Mini Charger 3. T-Type Connector 2. AC Cord 4. T-Type Connector INC. (Increase) Button 4 Start / Enter Button LED Indicator LCD Display BATT. Type | Stop Button Ventilation Fan DEC.
Input Functions BATT. Type/Stop Button Stop the progress of the current action or cycle back to the previous step / screen. DEC. Button Scroll through available menus or decrease parameter values. INC. Button CHANNEL button Scroll through available menus It is used to or increase switch from Channel A to B parameter values. or vice versa. Enter/Start Button Used to enter parameter or store parameter on screen & start charging.
Specifications | Features AC Input Voltage Charge Power Charge Current Range Balancing Port Current Drain Trickling Charging Current NiCd/NiMH Battery Cell Count LiPo/LiHV/LiFe/LiIon Cell Count Pb Battery Voltage Net Weight Dimensions 100 - 240V 50W x 2 0.1-5.0A 300mA/CELL 50mA-300mA & OFF 6-8 Cells 2-4 Cells 6/12V 500g 100 x 90 x 127mm Battery Memory (Data Store/Load): The RDX2 Mini is capable of storing up to 10 different charge profiles for your convenience.
Specifications | Features Continued Internal Independent Lithium Battery Balancer: The RDX2 Mini employs an individual-cell-voltage balancer. It is not necessary to connect an external balancer for balance charging. Adaptable to Various Types of Lithium Batteries: The RDX2 Mini will charge a variety of Lithium batteries such as Li-Ion, LiPo, LiFe and the new higher voltage LiHV batteries.
Charger Connections 1.) Connecting to Power Source: The RDX2 Mini is an AC charger only. Please insert the AC power cord to the wall socket (100-240V) directly to power it on. 2.) Connecting the Battery: NOTE: Before connecting any battery, it is absolutely essential to check one last time that the parameters were set correctly. If the settings are incorrect, the battery may be damaged and, in worse case scenarios, could even burst into flames or explode.
Program Flowchart INC BATT/PROGRAM LiPo BATT INC START ENTER START ENTER ENTER START ENTER START DEC LiHV BALANCE 2.0A 15.2V (4S) DEC LiFe CHARGE 2.0A 13.2V (4S) DEC Lilo CHARGE 2.0A 14.4V (4S) DEC LiHV CHARGE 2.0A 15.2V (4S) DEC INC LiPo STORAGE 2.0A 14.8V(4S) INC INC LiFe STORAGE 2.0A 13.2V (4S) INC INC Lilo STORAGE 2.0A 14.4V (4S) INC NiMH CHARGE CURRENT 2.0A INC INC LiHV STORAGE 2.0A 15.2V (4S) DEC NiCd CHARGE CURRENT 2.0A INC NiMH RE-PEAK 1 ENTER Pb NORMAL CHG 2.0A 12.
Charger Operations Initial Setup of the Charger: After connecting the battery, you are now ready to setup the charger to charge your specific type of battery. When the charger is first powered on, you will enter the BATT/PROGRAM by default. Select the type of chemistry cells you want to charge and hit the start button. Change the settings to match the voltage and charge rates for the battery you are charging based on the following instructions.
Charger Operations Continued Warning BEFORE YOU BEGIN CHARGING YOUR BATTERY, MAKE SURE YOU HAVE READ AND UNDERSTAND ALL OF THE WARNINGS AND SAFETY INFORMATION CONTAINED ON PAGES 3-8. DURING CHARGING, THE BATTERY SHOULD BE PLACED INSIDE A FIRE PROOF/ RETARDANT BAG AND ON A FIRE PROOF SURFACE, AWAY FROM OTHER COMBUSTIBLE OBJECTS. The following steps describe how to manually setup the RDX2 Mini: Caution ← BATT/PROGRAM LiPo BATT START/ENTER ← LiPo BALANCE 2.0A 11.v (3S) START/ENTER ← LiPo BALANCE 2.
Charger Operations Continued START/ENTER R shows the number of cells detected by the charger and S is the number of cells set by you at the previous screen. If both numbers are identical, press START/ENTER to start the charging process. 91% 12.14V 00:50:12 Charging Status Monitor During the charge process, the real-time status will be shown on screen. ← R:3SER S:3SSER Confirm (Enter) 1.5A A: 25% BAL B:NiMH 6.3V CHG 1.5A 91% 12.
Memory Set and Call Out The charger can store up to 10 different charge profiles for your convenience, and the stored profiles can be recalled quickly without having to go through the setup process. To program, press START/ENTER to make it blink then change the value with INC or DEC. The value will be stored by pressing START/ENTER once. All following screens are taking 2S(7.4V) LiPo battery as the example.
← Memory Set and Call Out Continued ← [ BATT MEMORY 1 ] C:4.9A START/ENTER > 3 SECONDS Indicate the charge current of the saved profile. Press the START/ENTER for 3 seconds to call out memory. Battery Memory Call Out Press the START/ENTER for 3 seconds to call out memory. ← LiPo BALANCE CHG 4.9A 7.4V (2S) BATTERY CHECK ← ....... ← R:2SER S:2SSER Confirm (Enter) 4.9A R shows the number of cells detected by the charger and S is the number of cells set by you at the previous screen.
Battery Resistance Meter W The user can check the battery’s total resistance. Please connect the balance wire attached to the battery to the balance socket and the XT60 male connector to the XT60 female connector in front of the charger. (-) (-) BATT/PROGRAM BATT RESISTANCE START (Negative wire is black) Press the START/ENTER button to access the Lithium Battery Meter program. ENTER BATTERY CHECK ....... 6.7 0.0 12.8mΩ 0.0mΩ Indicates each cell’s resistance. IN C TOTAL: 19.
Warning and Error Messages In case of an error, the screen will display the cause of the error and emit an audible sound. Reverse Polarity Incorrect polarity connected. Connection break The battery connection is interrupted. REVERSE POLARRITY CONNECT ERROR CHECK MAIN POINT BALANCE WIRES NOT CONNECTED INT. TEMP. TOO HI The battery connection is wrong. The balance wires are not connected while charging in balance mode. The internal temperature of the unit is too high.
System Setting When powered on for the first time, your RDX2 Mini charger will load with default values in the programmable user settings. The screen displays the following information in sequence and the user can change the value of the parameters on each screen. When you are ready to change the parameter values in the program, press START/ENTER to make it blink, and then select the appropriate values with INC or DEC. Store the value by pressing START/ENTER once.
Advanced System Set Up ITEM NiMH Sensitivity D.Peck 4mV NiMH Sensitivity D.Peck 4mV Key Beep ON Buzzer ON SELECTION Default: 4mV/Cell 3-15mV/Cell OFF/ON DESCRIPTION This program is for NiMH/NiCd batteries only. When the charger detects the delta peak value reaches the value you set, the charger will say the battery is fully charged. The beep sounds with the press of each button to confirm your action. The beep or melody sounds at various times during operation to alert different mode changes.
Commonly Used Terms A, mA: Unit of measurement relating to a charge or discharge current. 1000 mA = 1A (A = Ampere, mA = Milliampere). Ah, mAh: Unit of measurement for the capacity of a battery (Amperes x Time Unit; h = hour). If a pack is charged for one hour at a current of 2A, it has been fed 2Ah of energy. It receives the same quantity of charge (2Ah) if it is charged for 4 hours at 0.5A, or 15 minutes (=1/4 hour) at 8A. ‘C’ - Rating: Capacity is also referred to as the ‘C’ rating.
Commonly Used Terms [cont.] - LiPo: Multiply the total number of cells in the pack by 3.7. A 3-cell LiPo wired in series will have a nominal voltage of 11.1 volts (3 x 3.7). - Lilon: Multiply the total number of cells in the pack by 3.6. A 2-cell Lilon wired in a series will have a nominal voltage of 7.2 volts (2 x 3.6). - LiFe: Multiply the total number of cells in the pack by 3.3V. A 2-cell LiFe wired in a series will have a nominal voltage of 6.6 volts. (2 x 3.3).
Conformity Declarations D Hitec's RDX2 Mini satisfies all relevant and mandatory CE directives and complies with FCC Part 15 Subpart B: 2010.
Disposal and Prop Warning This symbol indicates that when this type of electronic device reaches the end of its service life, it cannot be disposed of with normal household waste and must be recycled. To find a recycling center near you, refer to the internet or your local phone directory for electronic waste recycling centers. STATE OF CALIFORNIA PROPOSITION 65 WARNING: This product contains chemicals known to the State of California to cause cancer.
Warranty and Service Continued ONE YEAR LIMITED WARRANTY: For a period of one year from the date of purchase HITEC RCD shall REPAIR OR REPLACE, at our option, defective equipment covered by this warranty, otherwise the purchaser and/ or consumer is responsible for any charges for the repair or replacement of the charger.
Warranty and Service Continued A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. REPAIR AND SERVICE. To have your Hitec charger serviced: 1. Visit the Hitec website at www.hitecrcd.com and download the service request form (under Support section). 2. Fill out the service request form completely and include a copy of your original receipt showing the purchase date. 3.
Hitec RCD | 9320 Hazard Way Suite D, San Diego, CA 92123 | www.hitecrcd.