Professional Balance Charger, Discharger
Hochleistungs Profi Balance
LADER / ENTLADER
6. Default User Preferences Setup
4
NiMH and NiCd Delta Peak Sensitivity Setting
This feature sets the cutoff voltage for the automatic charge
termination of a NiMH and NiCd battery pack. The setting 
can range from 3 to 15 mV per cell, the default is 4 mV 
for NiCd and NiMH, the parameters are set individually for 
NiCd and NiMH batteries. If the cutoff voltage is too high, 
there is a danger of overcharging the battery, if it is too 
low there is a possibility of premature charge termination. 
Refer to the battery manufacturer‘s specifi cations to de-
termine the proper setting. Once you 
have established the 
desired settings press „START/ENTER“
 to confi rm the set-
ting then press „INC“ to move on to the next parameter.
5
 Temperature Cutoff Setting
You can choose whether or not you want to use the automatic 
temperature cut off when using the optional temperature sen-
sors. When turned on you can set the maximum temperature 
at which the charger should allow the battery to reach during 
charging. Once a battery reaches this temperature, the charge 
or discharge process will be terminated to protect the battery. 
Once you have established the desired settings press „START/
ENTER“ to confi rm the setting then press „INC“ to move on 
to the next parameter.
6
Waste Time Setting
When charge/discharge cycling a battery the battery will 
become warm. You can set a time delay ranging from 0 to 
60 minutes after each charge/discharge process to allow 
the battery to cool down before starting the next charge/
discharge cycle. Once you have established the desired 
settings press „START/ENTER“ to confi rm the setting then 
press „INC“ to move on to the next parameter.
7
Safety Timer Setting
When the charge process starts, the integrated safety timer 
runs simultaneously. If an error occurs or the charge termi-
nation circuit cannot detect if the battery is fully charged, 
this setting will terminate the charge process to prevent 
overcharging. Use the following Safety Timer Calculation to 
determine the proper setting.
Safety Timer Setting Calculation
To determine the correct safety time setting when charging 
NiCd or NiMH batteries, divide the capacity by the current, 
and then divide the result by 11.9. 