CHARGING OF NICD/NIMH BATTERY
CHARGING OF NICD/NIMH BATTERY
This program is for charging NiCd/NiMH
batteries associated with R/C model applications.
Pressing the START/ENTER key to modify the
menu and then INC or DEC to change the
parameter settings. Press the START/ENTER
key to store the setting.
NIMH CHARGE Aut
CUR LIMIT 5.0A
INCDEC
-+
INCDEC
-+
Batt type
Stop
Start
Enter
‘>3 seconds’
This shows the real-time status of discharging;
you can press the BATT TYPE/STOP key to
stop discharging.
NIMH 2.0A 7.42V
CHG 022:45 00890
Battery
type
Elapsed
time
Charge current
Battery
voltage
Charged capacity
This program charges the battery using the charge current you set up.
In the “auto” function, you should set the upper limit of the charge
current to avoid damage by excessive charge current. Some batteries
of low resistance and capacity can lead to higher currents in the “auto”
charging mode. For these types of batteries, it will charge with the
current you set. You can change modes by pressing the START/ENTER
key to modify the current field and press INC and DEC simultaneously
to swap between Auto and Manual Mode. NOTE: Allowable fast charge
current: 1C-2C
CHARGING NICD/NIMH BATTERY IN THE CHARGE MODE
DISCHARGE OF NICD/NIMH BATTERY
Set the discharge current on the left and the
voltage cutoff on the right by pressing the
START/ENTER key for more than 3 seconds
to start the program. Discharge current can be
set from 0.1-1.0A and voltage cutoff from
0.1-25.0V.
NIMH DISCHARGE
1.0A 11.5A
INCDEC
-+
INCDEC
-+
Batt type
Stop
Start
Enter
‘>3 seconds’
This screen indicates the discharging state.
You can press the START/ENTER key to alter
the discharge current. Press the START/ENTER
key again to store the setting. Press the
BATT TYPE/STOP key to stop discharging. A
sound will emit to indicate the end of discharging.
NIMH 1.0A 7.42V
DSC 022:45 00890
Battery
type
Elapsed
time
Discharge
current
Battery
voltage
Discharged
capacity