User manual
- 13 -
INITIAL PARAMETER SETUP (USER’S SET-UP)
NIMH Sensitivity
D.Peak Default
NICD Sensitivity
D.Peak Default
Temp. Cut-off
 ON 80C
INCDEC
INCDEC
-+
INCDEC
-+
INCDEC
INCDEC
-+
INCDEC
INCDEC
-+
INCDEC
INCDEC
INCDEC
-+
INCDEC
-+
recognizes the cell count incorrectly at the 
beginning of the charge or discharge process, 
you may extend the time. Otherwise, you should 
use the default value.
This shows the cutoff voltage for the automatic 
charge termination of a NiMH and NiCd battery. 
The effective setting ranges from 5 to 20mV per 
cell. If the trigger voltage is set higher, there is a 
danger of overcharging the battery; if it is set 
lower, there is a possibility of premature 
termination. Please refer to the technical 
specification of the battery. 
(NiCd default: 12mV, NiMH default: 7mV)
The temperature cutoff will be turned on or off 
with the use of the optional temperature probe 
by contacting the surface of the battery. If it is 
on, set the maximum temperature at which the 
charger should allow the battery to reach during 
charging. Once a battery reaches this 
temperature, the process will be terminated to 
protect the battery. 
Waste time
CHG/DCHG 5min
The battery becomes warm after cycles of the 
charge/discharge process. The program will 
insert a time delay after each charge/discharge 
process to allow the battery enough time to cool 
down before beginning the next cycle of charge/
discharge. The setting ranges from 0 to 60 minutes