X4 AC Pro AC/DC 4 Port Multicharger Manual
2928
Pb (Lead Acid) Battery Program
This program is only suitable for charging Pb (lead-acid) batteries with nominal
voltages of 2 to 20V. A Pb (lead-acid) battery is signi cantly di erent from NiCD/
NiMH batteries. Pb batteries can only deliver current lower in comparison
to their capacity. The same restriction applies to the charging process.
Consequently, the optimum charge current can only be 1/10 of the capacity.
A Pb battery cannot be used for fast charging. Please follow the instructions
provided by the battery manufacturer.
The X4 AC Pro o ers the following Pb charge modes: Charge and Discharge.
Pb Charge Mode:
BEFORE YOU BEGIN CHARGING/DISCHARGING YOUR BATTERY, MAKE
SURE YOU HAVE READ AND UNDERSTAND ALL OF THE WARNINGS AND
SAFETY INFORMATION CONTAINED ON PAGES 3 ~ 7.
After selecting the correct battery type, use the INC or
DEC buttons to change it to the “CHARGE“ mode.
Press the START/ENTER button and the amp rate value
will begin ashing. Use the INC or DEC buttons to adjust
the value to the desired charge rate. The amp rate should
be set to 1/10 of capacity. For example if you are charging a 7Ah battery the charge
rate should be set to 0.7A. Follow the instructions provided with your battery when
setting the amp rate.
Press the START/ENTER button again and the voltage
rate value will begin ashing. Use the INC or DEC
buttons to set the voltage and number of cells.
Press and hold the START/ENTER button and charging will begin.
Once charging has commenced, the charger will display
the following real-time information: battery type,
charging current, battery voltage, charging time and charged capacity.
When charging is complete, the screen will read “FINISHED” and the charger will emit
a chiming sound.
Warning
2.0A 6.0V(3P)
Pb CHARGE
2.0A 6.0V(3P)
Pb
CHARGE
2.0A 6.0V(3P)
Pb CHARGE
Pb 1.3A 5.90V
CHG 005:33 00581
66
Pb (Lead Acid) Battery Program
Pb Discharge Mode:
After selecting the correct battery type, use the INC or
DEC buttons to change it to the “CHARGE“ mode.
Press the START/ENTER button and the amp rate value
will begin ashing. Use the INC or DEC buttons to adjust
the value to the desired discharge rate. The discharge
amperage can be set between 0.1 and 2.0 Amps
Press the START/ENTER button again and the voltage
rate value will begin ashing. Use the INC or DEC
buttons to set the voltage and number of cells.
Press and hold the START/ENTER button and charging will begin.
Once charging has commenced, the charger will display
the following real-time information: battery type,
charging current, battery voltage, charging time and
charged capacity.
When charging is complete, the screen will read “FINISHED” and the charger will emit
a chiming sound.
2.0A 6.0V(3P)
Pb DISCHARGE
2.0A 6.0V(3P)
Pb DISCHARGE
2.0A 6.0V(3P)
Pb DISCHARGE
Pb 1.3A 5.90V
DCH 005:33 00581
66
Other Information Displayed During the Process
Pressing the INC or DEC buttons during the charging or discharging process al-
lows you to see a variety of other information on the screen.
Input voltage from internal or external power source.
Internal and external temperatures. External Tempera-
ture requires optional temperature sensor. #44159
Cut-o temperature when using external temperature
sensor.
Safety timer ON and duration of time in minutes.
Capacity cut-o ON and set value of the capacity limit.
14.82V
IN Power Voltage
Int. Temp 37°C
Ext. Temp ----
ON 50°C
Temp Cut-Off
ON 120min
Safety Time
Capacity Cut-Off
ON 5000mAh