X4 AC Pro AC/DC 4 Port Multicharger Manual

2928
Pb (Lead Acid) Battery Program
This program is only suitable for charging Pb (lead-acid) batteries with nominal
voltages of 2 to 20V. A Pb (lead-acid) battery is signi cantly di erent from NiCD/
NiMH batteries. Pb batteries can only deliver current lower in comparison
to their capacity. The same restriction applies to the charging process.
Consequently, the optimum charge current can only be 1/10 of the capacity.
A Pb battery cannot be used for fast charging. Please follow the instructions
provided by the battery manufacturer.
The X4 AC Pro o ers the following Pb charge modes: Charge and Discharge.
Pb Charge Mode:
BEFORE YOU BEGIN CHARGING/DISCHARGING YOUR BATTERY, MAKE
SURE YOU HAVE READ AND UNDERSTAND ALL OF THE WARNINGS AND
SAFETY INFORMATION CONTAINED ON PAGES 3 ~ 7.
After selecting the correct battery type, use the INC or
DEC buttons to change it to the “CHARGE“ mode.
Press the START/ENTER button and the amp rate value
will begin  ashing. Use the INC or DEC buttons to adjust
the value to the desired charge rate. The amp rate should
be set to 1/10 of capacity. For example if you are charging a 7Ah battery the charge
rate should be set to 0.7A. Follow the instructions provided with your battery when
setting the amp rate.
Press the START/ENTER button again and the voltage
rate value will begin  ashing. Use the INC or DEC
buttons to set the voltage and number of cells.
Press and hold the START/ENTER button and charging will begin.
Once charging has commenced, the charger will display
the following real-time information: battery type,
charging current, battery voltage, charging time and charged capacity.
When charging is complete, the screen will read “FINISHED” and the charger will emit
a chiming sound.
Warning
2.0A 6.0V(3P)
Pb CHARGE
2.0A 6.0V(3P)
Pb
CHARGE
2.0A 6.0V(3P)
Pb CHARGE
Pb 1.3A 5.90V
CHG 005:33 00581
66
Pb (Lead Acid) Battery Program
Pb Discharge Mode:
After selecting the correct battery type, use the INC or
DEC buttons to change it to the “CHARGE“ mode.
Press the START/ENTER button and the amp rate value
will begin  ashing. Use the INC or DEC buttons to adjust
the value to the desired discharge rate. The discharge
amperage can be set between 0.1 and 2.0 Amps
Press the START/ENTER button again and the voltage
rate value will begin  ashing. Use the INC or DEC
buttons to set the voltage and number of cells.
Press and hold the START/ENTER button and charging will begin.
Once charging has commenced, the charger will display
the following real-time information: battery type,
charging current, battery voltage, charging time and
charged capacity.
When charging is complete, the screen will read “FINISHED” and the charger will emit
a chiming sound.
2.0A 6.0V(3P)
Pb DISCHARGE
2.0A 6.0V(3P)
Pb DISCHARGE
2.0A 6.0V(3P)
Pb DISCHARGE
Pb 1.3A 5.90V
DCH 005:33 00581
66
Other Information Displayed During the Process
Pressing the INC or DEC buttons during the charging or discharging process al-
lows you to see a variety of other information on the screen.
Input voltage from internal or external power source.
Internal and external temperatures. External Tempera-
ture requires optional temperature sensor. #44159
Cut-o temperature when using external temperature
sensor.
Safety timer ON and duration of time in minutes.
Capacity cut-o ON and set value of the capacity limit.
14.82V
IN Power Voltage
Int. Temp 37°C
Ext. Temp ----
ON 50°C
Temp Cut-Off
ON 120min
Safety Time
Capacity Cut-Off
ON 5000mAh