User Manual

3130
System Settings
When powered on for the  rst time, your X4 AC Pro charger will load with default
values in the programmable user settings. Each channel has its own system
setting allowing for a great of  exibility in controlling the various processes.
Use the INC or DEC buttons to scroll to the BATT/PROGRAM SYSTEM SETTING->
screen, press the START/ENTER button to enter the systems setting menu. The
screen displays the following information in sequence and the user can change
the value of the parameters on each screen.
Celsius
Temperature Unit
ON 50°C
Temp Cut-Off
ON 120min
Safety Timer
Capacity Cut-Off
ON 5000mAh
Item Selection Description
OFF / ON
1 ~ 720
Minutes
When you start a charge process,
the internal safety timer auto-
matically starts running at the same
time. It is programmed to prevent
overcharging, if the battery proves
to be faulty or if the termination cir-
cuit cannot detect the full battery.
The value of the safety timer should
be generous enough to allow full
charging of the battery.
OFF / ON
100 ~ 50000
mAh
This sets the maximum charge
capacity that will be supplied to
the battery during charge. If the
delta peak voltage is not detected
for any reason or the safety timer
has not expired, this feature will
automatically stop the process at
the selected capacity value.
OFF/ ON
20C ~ 80C
68F ~ 176 F)
NICD/NiMH batteries internal
Chemical reaction will cause the
temperature of the battery to rise.
If the temperature limit is reached,
the process will be terminated.
Celsius
Fahrenheit
Adjusts the units the temperature is
measured in.
Item Selection Description
1 - 60
Minutes
Rest time allows the battery to cool
down between charging/discharg-
ing cycles
Default: 4mV/Cell
3 ~ 15mV/Cell
This setting is for NiMH/NiCd
batteries only. When the charger
detects that the delta peak value
you set has been reached, the
charger will indicate the battery is
fully charged.
ON / OFF
Key Beep sounds every time you
press a button. Buzzer beep or
melody sounds at various instanc-
es during operation to alert you to
certain process events.
10.0 ~ 11.0V
This setting controls the DC input
voltage. If the voltage drops below
the value you set the charging
operation will be terminated to
protect the charger.
ON / OFF
The default setting for charg-
ing Lithium batteries is to use a
balance adaptor to connect the
battery and charger in Charge, Fast
Charge, Balance Charge and Stor-
age modes. This function could be
disabled here.
O - 100
See Page 12 for a complete expla-
nation of the Power Distribution
Function
Press ENTER to load the factory
default settings
Indicates the hardware and  rm-
ware versions
CHG>DCHG 10min
Rest Time
Enter
Load Factory Set
HW 1:01 SW1:00
Version
Cut-Off 11.0V
DC Input Low
Buzzer ON
Key Beep ON
100W
AC Max Power Set
ON
BAL. Connection
D.Peak Default
NiMH Sensitivity
D.Peak Default
NiCd Sensitivity