User Manual
2726
NiMH / NiCd Battery Program (cont.)
IN REPEAK MODE, THE X4 AC PRO USES THE CHARGE AMPERAGE
AND VOLTAGE SETTINGS ENTERED IN CHARGE MODE SEE PAGE 20.
Note
After selecting the correct battery type, use the INC or
DEC buttons to select the “RE-PEAK” mode. Press the
START/ENTER button to con rm.
The number of Re-Peak cycles will begin ashing use
the INC or DEC buttons to select the number of Re-
peak cycles you want to perform up to 3 total cycles.
Program Start
Press and hold the START START/ENTER button until you see “BATTERY
CHECK...” the battery should then begin Re-Peak charging.
Once Re-Peak process has begun, the charger will
display the following real-time information: battery
type, charging current, battery voltage, elapsed time
and charged capacity.
Once the Re-Peak process has completed, the screen will read “END: RE-PEAK”
and the charger will emit a chiming sound. The X4 AC Pro will display the
charge/discharge capacity for each cycle. Using the + and - buttons, you can
scroll through this data for each cycle.
NiCD/NiMH Cycle Mode
The X4 AC Pro makes cycling of NiCD/NiMH batteries easy. The process of
discharging and recharging (cycling) can be achieved automatically with one
simple step and will improve the performance of NiCD/NiMH batteries. We
strongly recommend cycling any battery that has been discharged and stored
for a period of time. This will increase battery life and improve performance.
FOR CYCLING, THE X4 AC PRO USES THE CHARGE/DISCHARGE AMPERAGE
AND VOLTAGE SETTINGS ENTERED IN THE CHARGE AND DISCHARGE
MODES SEE PAGES 20 ~ 22.
After selecting the correct battery type use the INC
and DEC to scroll to CYCLE Mode. Press the START/
ENTER button to con rm.
1
NiMH RE-PEAK
1
NiMH RE-PEAK
NiMH 1.3A 5.90V
RPC 005:33 00581
Note
CHG>DCHG 1
NiMH CYCLE
66
NiMH / NiCd Battery Program (cont.)
The “CHG>DCHG” option will rst charge the battery
and then discharge the battery. If this screen does not
currently show the cycling option you desire, press the
START/ENTER button once and this setting will begin ashing. Use the INC or DEC
buttons to change this setting.
Pressing the START/ENTER button again will cause the
number of cycles option to begin ashing. Use the INC
or DEC buttons to change this to the number of cycles
you want the X4 AC Pro to run. The X4 AC Pro can cycle the battery a maximum of 5
times consecutively.
Program Start
Press and hold the START START/ENTER button until you see “BATTERY
CHECK...” the battery should then begin the cycle process.
Once cycling has commenced, the charger will display
the following real-time information: battery type,
charging/discharging current, battery voltage, charging
time and charged capacity. You will also see “D>C“ or “C>D“. This will indicate
which cycling order you have chosen. Either “D“ or “C“ will be ashing. This ashing
indicates which part of the cycle is currently being executed.
Once the cycling process is complete, the screen will read “END: CYCLE” and the
charger will emit a chiming sound. The X4 AC Pro will display the charge/discharge
capacity for each cycle. Using the INC. and DEC. buttons, you can scroll through this
data for each cycle.
CHG>DCHG 3
NiMH CYCLE
CHG>DCHG 1
NiMH CYCLE
NiMH 1.3A 5.90V
C>D 005:33 00581
66
NiMH Sensitivity
D.Peak 4mV/CELL
Ext. Temp ----
Int. Temp 37 C
Safety Time
ON 120min
In Power Voltage
12.6 V
Temp Cut-Off
ON 50 C
Capacity Cutoff
ON 500mAh
Additional Information Displayed During the Process
Pressing the INC or DEC buttons during the charging or discharging process al-
lows you to see a variety of other information on the screen.
Delta Peak voltage
sensitivity setting
External / Internal
temperatures
Safety timer setting
Temperature Cut-o
setting
Capacity Cut-o
setting
Input Voltage