User's Manual
“P” Group: Expansion Card Functions
Configuring Drive 
Parameters
3–66
NOTE: Parameters P044 to P049 are available only in inverters with manufacturing code 
x8K xxxxxx xxxxx or later. The manufacturing code is printed on the product specifications 
labels, located on the front and side of the inverter housing.
P022 Feed-forward gain 
setting
Range is 0.00 top 99.99 / 
100.0
✘ ✔ 0.00 0.00 0.00 —
>P022 FEEDBACK
FFWG 000.00
P023 Position loop gain 
setting
Range is 0.00 to 99.99 / 
100.0
✘ ✔ 0.50 0.50 0.50 —
>P023 FEEDBACK
G 000.50
P025 Temperature compensa-
tion thermistor enable
Allows for motor-mounted 
thermistor to calibrate 
output to motor temperature
Two option codes:
00 Disable
01 Enable
✘ ✔ 00 00 00 —
>P025 FEEDBACK
R2-ADJ  OFF
P026 Over-speed error
detection level setting
Range is 0.0 to 150.0% ✘ ✔
135.0 135.0 135.0
%
>P026 FEEDBACK
0SPD 135.0%
P027 Speed deviation error 
detection level setting
Range is 0.00 to 99.99 / 
120Hz
✘ ✔ 7.50 7.50 7.50 —
>P027 FEEDBACK
NER 007.50Hz
P031 Accel/decel time input 
selection
Three options:
00 Inverter
01 Expansion card 1
02 Expansion card 2
✘ ✘ 00 00 00 —
>P031 ACC/DEC
SELECT  REM
P032 Positioning command 
input selection
Three options:
00 Inverter
01 Expansion card 1
02 Expansion card 2
✘ ✔ 00 00 00 —
>P032 P-SET
SELECT  REM
P044 DeviceNet comm 
watchdog timer
Range is 0.00 99.99 seconds ✘ ✘ 1.00 1.00 1.00 —
>P044 DEVICENET
TIMER 01.00s
P045 Inverter action on 
DeviceNet comm error
Five options:
00 Trip
01 Decelerate and trip
02 Hold last speed
03 Free run stop
04 Decelerate and stop
✘ ✘ 01 01 01 —
>P045 DEVICENET
T-OUT  FTP
P046 DeviceNet polled I/O: 
Output instance number
Three settings:
20, 21, 100
✘ ✘ 21 21 21 —
>P046 DEVICENET
O-AS-INS  021
P047 DeviceNet polled I/O: 
Input instance number
Three settings:
70, 71, 101
✘ ✘ 71 71 71 —
>P047 DEVICENET
O-AS-INS  071
P048 Inverter action on 
DeviceNet idle mode 
Five options:
00 Trip
01 Decelerate and trip
02 Hold last speed
03 Free run stop
04 Decelerate and stop
✘ ✘ 01 01 01 —
>P048 DEVICENET
IDLE  FTP
P049 DeviceNet motor poles 
setting for RPM
Range is 00 to 38 (even 
numbers only)
✘ ✘ 0 0 0 poles
>P049 DEVICENET
P  00P
“P” Function
Run 
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)