Service Manual

Table Of Contents
11. Electrial checks of main parts
440
SMGB0079 rev.0 - 01/2013
11.1 Inverter
11.1.1 Specications of inverter
Applicable model
RAS-(4-6)HNPE RAS-(4-6)HNCE
RAS-(8-12)
HN(P/C)(E)
RAS-(2-2.5)HVNP
RAS-3HVNC
RAS-3HVNPE RAS-(4-6)HVNPE RAS-(4-6)HVNCE
Applicable power source 3 Phase 400V 50 Hz 1 Phase. 230V 50 Hz
Output current 24.0A 16.0A 45.0A 10.5A 16.0A 24.0A 16.0A
Control Method Vector control
Range output frequency 20-115HZ 31-115HZ 20-115HZ 15-115HZ
Accuracy of frequency 0.01Hz at applicable frequency range
Output / characteristics
Conditions:
1 Power source voltage AC380/415V
2 Non-loading (free output)
3 Ammeter type volt-meter (X1.1)
Conditions:
1 Power source voltage AC220/240V
2 Non-loading (free output)
3 Ammeter type volt-meter (X1.1)
Soft start stop 0.125–3.00 Hz/s