Service Manual

Table Of Contents
8. Troubleshooting
208
SMGB0079 rev.0 - 01/2013
Alarm code
06
Excessively low voltage or excessively high voltage for the inverter
The RUN LED ickers and “ALARM” is displayed on the remote control switch.
The unit number, the alarm code and the unit code are alternately displayed on the set temperature section.
The unit number and the alarm code are displayed on the display of the outdoor unit PCB.
- This alarm code is displayed when the voltage between terminal “P” and “N” of Inverter is insufcient and the alarm
has three occurrences in 30 minutes. If the number of occurrences is smaller than two, the retry operation is per-
formed. The alarm code “06.” Means fan controller Abnormal Operation.
RAS-(2-2.5)HVNP / RAS-3HVNC
N O T E
RelpaceelectricalboxonlywhenLEDisOFF.