Service Manual
Table Of Contents
- Contents
 - 1. General information
 - 2. Unit Installation
 - 3. Piping work and refrigerant charge
 - 4. Electrical wiring
- 4.1 General notes
 - 4.2 Electrical wiring connection for the outdoor unit
 - 4.3 Setting the DIP switches for the outdoor unit
 - 4.4 Common wiring
 - 4.5 H-LINK II system
 - 4.6 System Control
 - 4.7 Electrical wiring diagrams
- 4.7.1 RAS-(2-2.5)HVNP / RAS-3HVNC (1~ 230V 50Hz)
 - 4.7.2 RAS-3HVNPE (1~ 230V 50Hz)
 - 4.7.3 RAS-(4-6)HVNPE (1~ 230V 50Hz)
 - 4.7.4 RAS-(4-6)HNPE (3N~ 400V 50Hz)
 - 4.7.5 RAS-(4-6)HVNCE (1N~ 230V 50Hz)
 - 4.7.6 RAS-(4-6)HNCE (3N~ 400V 50Hz)
 - 4.7.7 RAS-(8-10)HN(P/C)E (3N~ 400V 50Hz)
 - 4.7.8 RAS-12HNP (3N~ 400V 50Hz) - Preliminary data
 - 4.7.9 RAS-12HNC (3N~ 400V 50Hz) - Preliminary data
 
 
 - 5. Control System
- 5.1 Device control system
 - 5.2 Outdoor units PCB
 - 5.3 Protection and safety control
 - 5.4 Standard operation sequence
 - 5.5 Standard control functions
- 5.5.1 Freezing protection during cooling process or dry operation
 - 5.5.2 Prevention Control for High Pressure Increase during Cooling Operation
 - 5.5.3 Prevention control for excessively high discharge gas temperature
 - 5.5.4 Activation for protection device control
 - 5.5.5 Preheating control of compressor
 - 5.5.6 Prevention control for high pressure increase
 
 
 - 6. Optional functions
 - 7. Test run
- 7.1 Checking procedure before the test run
 - 7.2 Test run procedure using the remote control switch (PC-ART)
 - 7.3 Test run procedure using the remote control switch (PC-ARF)
 - 7.4 Test run procedure using the wireless remote control switch (PC-LH3A/B)
 - 7.5 Test run procedure from the outdoor unit side
 - 7.6 Check list
 
 - 8. Troubleshooting
- 8.1 Initial troubleshooting
 - 8.2 Troubleshooting procedure
 - 8.3 Troubleshooting in check mode
 - 8.4 Checking procedure for main parts
- 8.4.1 Procedure for checking the DIP-IPM inverter for indoor and outdoor units
 - 8.4.2 Checking capacitors CB1 & CB2.
 - 8.4.3 Fault diagnosis of DC fan motor.
 - 8.4.4 Checking procedure for the electronic expansion valve for indoor and outdoor units
 - 8.4.5 Checking procedure for AC fan motor
 - 8.4.6 Checking procedure for other parts
 
 
 - 9. Spare parts
 - 10. Servicing
- 10.1 Introduction
 - 10.2 Servicing for Outdoor Units RAS-(2-2.5)HVNP and RAS-3HVNC
 - 10.3 Servicing for Premium series
- 10.3.1 Outdoor unit RAS-3HVNPE
- 10.3.1.1 Removing service cover
 - 10.3.1.2 Remove outlet grille
 - 10.3.1.3 Removing upper cover
 - 10.3.1.4 Removing bottom service cover and rear cover
 - 10.3.1.5 Removing outdoor fan motor
 - 10.3.1.6 Removing electrical box
 - 10.3.1.7 Removing the compressor
 - 10.3.1.8 Removing the High pressure switch and Pressure switch for control
 - 10.3.1.9 Opening electrical box (P plate)
 - 10.3.1.10 Removing Reversing valve coil
 - 10.3.1.11 Removing electronic expansion valve coil
 - 10.3.1.12 Removing solenoid valve coil (SVC)
 - 10.3.1.13 Removing reversing valve
 - 10.3.1.14 Removing Electronic expansion Valve and Solenoid Valve
 - 10.3.1.15 Removing electrical components
 - 10.3.1.16 Removing other electrical components
 
 - 10.3.2 Outdoor units RAS-(4-6)H(V)NPE
- 10.3.2.1 Removing service cover
 - 10.3.2.2 Removing air outlet grille
 - 10.3.2.3 Removing upper cover
 - 10.3.2.4 Removing the bottom service cover and rear cover
 - 10.3.2.5 Removing outdoor fan motor
 - 10.3.2.6 Removing electrical box
 - 10.3.2.7 Removing the compressor
 - 10.3.2.8 Removing the High pressure switch and Pressure switch for control
 - 10.3.2.9 Opening electrical box (P plate)
 - 10.3.2.10 Removing Reversing valve coil
 - 10.3.2.11 Removing electronic expansion valve coil
 - 10.3.2.12 Removing solenoid valve coil (SVA and SVC)
 - 10.3.2.13 Removing reversing valve
 - 10.3.2.14 Removing Electronic expansion Valve and Solenoid Valve
 - 10.3.2.15 Removing electrical components
 - 10.3.2.16 Removing other electrical components
 
 - 10.3.3 Oudoor units RAS-(8-10)HNPE
- 10.3.3.1 Removing service cover
 - 10.3.3.2 Removing air outlet grille
 - 10.3.3.3 Removing upper cover
 - 10.3.3.4 Removing the bottom service cover and rear cover
 - 10.3.3.5 Removing outdoor fan motor
 - 10.3.3.6 Removing electrical box
 - 10.3.3.7 Removing the compressor
 - 10.3.3.8 Removing High pressure switch and pressure switch for control
 - 10.3.3.9 Opening electrical box (P-Mounting Plate)
 - 10.3.3.10 Removing reversing valve coil
 - 10.3.3.11 Removing electronic expansion valve coil
 - 10.3.3.12 Removing solenoid valve coil (SVA and SVC)
 - 10.3.3.13 Removing reversing valve
 - 10.3.3.14 Removing Electronic expansion Valve and Solenoid Valve
 - 10.3.3.15 Removing electrical components
 - 10.3.3.16 Removing other electrical components
 
 - 10.3.4 Outdoor Units RAS-12HNP
- 10.3.4.1 Removing service cover
 - 10.3.4.2 Removing air outlet grille
 - 10.3.4.3 Removing upper cover
 - 10.3.4.4 Removing the bottom service cover and rear cover
 - 10.3.4.5 Removing outdoor fan motor
 - 10.3.4.6 Removing electrical box
 - 10.3.4.7 Removing the compressor
 - 10.3.4.8 Removing High pressure switch and pressure switch for control
 - 10.3.4.9 Removing reversing and solenoid valves coils
 - 10.3.4.10 Removing electronic expansion valve coil
 - 10.3.4.11 Removing reversing valve
 - 10.3.4.12 Removing Electronic expansion Valve and Solenoid Valve
 - 10.3.4.13 Removing electrical components
 - 10.3.4.14 Removing other electrical components
 
 
 - 10.3.1 Outdoor unit RAS-3HVNPE
 - 10.4 Servicing for Standard Series
- 10.4.1 Outdoor Units RAS-(4-6)H(V)NCE
- 10.4.1.1 Removing service cover
 - 10.4.1.2 Remove outlet grille
 - 10.4.1.3 Removing upper cover
 - 10.4.1.4 Removing bottom service cover and rear cover
 - 10.4.1.5 Removing outdoor fan motor
 - 10.4.1.6 Removing electrical box
 - 10.4.1.7 Removing the compressor
 - 10.4.1.8 Removing the High pressure switch and Pressure switch for control
 - 10.4.1.9 Opening electrical box (P plate)
 - 10.4.1.10 Removing Reversing valve coil
 - 10.4.1.11 Removing electronic expansion valve coil
 - 10.4.1.12 Removing solenoid valve coil (SVA)
 - 10.4.1.13 Removing reversing valve
 - 10.4.1.14 Removing Electronic expansion valve and Solenoid valve
 - 10.4.1.15 Removing electrical components
 - 10.4.1.16 Removing other electrical components
 
 - 10.4.2 Outdoor Units RAS-(8-10)HNCE
- 10.4.2.1 Removing service cover
 - 10.4.2.2 Removing air outlet grille
 - 10.4.2.3 Removing upper cover
 - 10.4.2.4 Removing the bottom service cover and rear cover
 - 10.4.2.5 Removing outdoor fan motor
 - 10.4.2.6 Removing electrical box
 - 10.4.2.7 Removing the compressor
 - 10.4.2.8 Removing High pressure switch and pressure switch for control
 - 10.4.2.9 Opening electrical box (P-Mounting Plate)
 - 10.4.2.10 Removing reversing valve coil
 - 10.4.2.11 Removing electronic expansion valve coil
 - 10.4.2.12 Removing solenoid valve coil (SVA)
 - 10.4.2.13 Removing reversing valve
 - 10.4.2.14 Removing Electronic expansion Valve and Solenoid Valve
 - 10.4.2.15 Removing electrical components
 - 10.4.2.16 Removing other electrical components
 
 - 10.4.3 Outdoor Units RAS-12HNC
- 10.4.3.1 Removing service cover
 - 10.4.3.2 Removing air outlet grille
 - 10.4.3.3 Removing upper cover
 - 10.4.3.4 Removing the bottom service cover and rear cover
 - 10.4.3.5 Removing outdoor fan motor
 - 10.4.3.6 Removing electrical box
 - 10.4.3.7 Removing High pressure switch and pressure switch for control
 - 10.4.3.8 Opening electrical box (P-Mounting Plate)
 - 10.4.3.9 Removing reversing and solenoid valves coils
 - 10.4.3.10 Removing electronic expansion valve coil
 - 10.4.3.11 Removing reversing valve
 - 10.4.3.12 Removing Electronic expansion Valve and Solenoid Valve
 - 10.4.3.13 Removing electrical components
 - 10.4.3.14 Removing other electrical components
 
 
 - 10.4.1 Outdoor Units RAS-(4-6)H(V)NCE
 
 - 11. Electrial checks of main parts
 - 12. Maintenance notes
- 12.1 General notes
- 12.1.1 Checking the power source and the wiring connection
 - 12.1.2 Burnt-out compressor due to an insufficient refrigerant charge
 - 12.1.3 Insufficient cooling performance when a long piping is applied
 - 12.1.4 Abnormally high operation sound (in the ceiling type indoor unit).
 - 12.1.5 Alarm code “31”
 - 12.1.6 Not cooling well due to insufficient installation space for the outdoor unit
 
 - 12.2 Maintenance work
 - 12.3 Service and maintenance record
 - 12.4 Service and maintenance record using the 7-segment display
 - 12.5 Service and maintenance record by remote control switch
 - 12.6 Pump-down method for replacing the compressor
 
 - 12.1 General notes
 - General information
 - Safety
 - Product guide
 - Safety summary
 - Transportation of outdoor unit
 - Center of gravity
 - Factory-supplied accessories for RAS-12HN(P/C)
 - Installation space (Initial ckeck)
 - Place provision
 - Optional parts and installation
 - General notes before performing pipe work
 - Piping connection for outdoor unit
 - Refrigerant piping range
 - Refrigerant charge
 - Caution in case of refrigerant leakage
 - Piping work for compatibility with the piping of current installations where is used R22 or R407C.
 - Drain piping
 - General notes
 - Electrical wiring connection for the outdoor unit
 - Setting the DIP switches for the outdoor unit
 - Common wiring
 - H-LINK II system
 - System Control
 - Electrical wiring diagrams
- RAS-(2-2.5)HVNP / RAS-3HVNC (1~ 230V 50Hz)
 - RAS-3HVNPE (1~ 230V 50Hz)
 - RAS-(4-6)HVNPE (1~ 230V 50Hz)
 - RAS-(4-6)HNPE (3N~ 400V 50Hz)
 - RAS-(4-6)HVNCE (1N~ 230V 50Hz)
 - RAS-(4-6)HNCE (3N~ 400V 50Hz)
 - RAS-(8-10)HN(P/C)E (3N~ 400V 50Hz)
 - RAS-12HNP (3N~ 400V 50Hz) - Preliminary data
 - RAS-12HNC (3N~ 400V 50Hz) - Preliminary data
 
 - Device control system
 - Outdoor units PCB
 - Protection and safety control
 - Standard operation sequence
 - Standard control functions
- Freezing protection during cooling process or dry operation
 - Prevention Control for High Pressure Increase during Cooling Operation
 - Prevention control for excessively high discharge gas temperature
 - Activation for protection device control
 - Preheating control of compressor
 - Prevention control for high pressure increase
 
 - Optional input and output signals (By 7-segment display)
 - Optional functions (By 7-segment display)
 - Optional functions (By remote control switch)
 - Checking procedure before the test run
 - Test run procedure using the remote control switch (PC-ART)
 - Test run procedure using the remote control switch (PC-ARF)
 - Test run procedure using the wireless remote control switch (PC-LH3A/B)
 - Test run procedure from the outdoor unit side
 - Check list
 - Initial troubleshooting
 - Troubleshooting procedure
 - Troubleshooting in check mode
 - Checking procedure for main parts
 - RAS-(2-2.5)HVNP
 - RAS-3HVNC
 - RAS-3HVNPE
 - RAS-(4-6)H(V)NPE
 - RAS-(4-6)H(V)NCE
 - RAS-(8-10)HN(P/C)E
 - RAS-12HN(P/C)
 - Introduction
 - Servicing for Outdoor Units RAS-(2-2.5)HVNP and RAS-3HVNC
 - Servicing for Premium series
- Outdoor unit RAS-3HVNPE
- Removing service cover
 - Remove outlet grille
 - Removing upper cover
 - Removing bottom service cover and rear cover
 - Removing outdoor fan motor
 - Removing electrical box
 - Removing the compressor
 - Removing the High pressure switch and Pressure switch for control
 - Opening electrical box (P plate)
 - Removing Reversing valve coil
 - Removing electronic expansion valve coil
 - Removing solenoid valve coil (SVC)
 - Removing reversing valve
 - Removing Electronic expansion Valve and Solenoid Valve
 - Removing electrical components
 - Removing other electrical components
 
 - Outdoor units RAS-(4-6)H(V)NPE
- Removing service cover
 - Removing air outlet grille
 - Removing upper cover
 - Removing the bottom service cover and rear cover
 - Removing outdoor fan motor
 - Removing electrical box
 - Removing the compressor
 - Removing the High pressure switch and Pressure switch for control
 - Opening electrical box (P plate)
 - Removing Reversing valve coil
 - Removing electronic expansion valve coil
 - Removing solenoid valve coil (SVA and SVC)
 - Removing reversing valve
 - Removing Electronic expansion Valve and Solenoid Valve
 - Removing electrical components
 - Removing other electrical components
 
 - Oudoor units RAS-(8-10)HNPE
- Removing service cover
 - Removing air outlet grille
 - Removing upper cover
 - Removing the bottom service cover and rear cover
 - Removing outdoor fan motor
 - Removing electrical box
 - Removing the compressor
 - Removing High pressure switch and pressure switch for control
 - Opening electrical box (P-Mounting Plate)
 - Removing reversing valve coil
 - Removing electronic expansion valve coil
 - Removing solenoid valve coil (SVA and SVC)
 - Removing reversing valve
 - Removing Electronic expansion Valve and Solenoid Valve
 - Removing electrical components
 - Removing other electrical components
 
 - Outdoor Units RAS-12HNP
- Removing service cover
 - Removing air outlet grille
 - Removing upper cover
 - Removing the bottom service cover and rear cover
 - Removing outdoor fan motor
 - Removing electrical box
 - Removing the compressor
 - Removing High pressure switch and pressure switch for control
 - Removing reversing and solenoid valves coils
 - Removing electronic expansion valve coil
 - Removing reversing valve
 - Removing Electronic expansion Valve and Solenoid Valve
 - Removing electrical components
 - Removing other electrical components
 
 
 - Outdoor unit RAS-3HVNPE
 - Servicing for Standard Series
- Outdoor Units RAS-(4-6)H(V)NCE
- Removing service cover
 - Remove outlet grille
 - Removing upper cover
 - Removing bottom service cover and rear cover
 - Removing outdoor fan motor
 - Removing electrical box
 - Removing the compressor
 - Removing the High pressure switch and Pressure switch for control
 - Opening electrical box (P plate)
 - Removing Reversing valve coil
 - Removing electronic expansion valve coil
 - Removing solenoid valve coil (SVA)
 - Removing reversing valve
 - Removing Electronic expansion valve and Solenoid valve
 - Removing electrical components
 - Removing other electrical components
 
 - Outdoor Units RAS-(8-10)HNCE
- Removing service cover
 - Removing air outlet grille
 - Removing upper cover
 - Removing the bottom service cover and rear cover
 - Removing outdoor fan motor
 - Removing electrical box
 - Removing the compressor
 - Removing High pressure switch and pressure switch for control
 - Opening electrical box (P-Mounting Plate)
 - Removing reversing valve coil
 - Removing electronic expansion valve coil
 - Removing solenoid valve coil (SVA)
 - Removing reversing valve
 - Removing Electronic expansion Valve and Solenoid Valve
 - Removing electrical components
 - Removing other electrical components
 
 - Outdoor Units RAS-12HNC
- Removing service cover
 - Removing air outlet grille
 - Removing upper cover
 - Removing the bottom service cover and rear cover
 - Removing outdoor fan motor
 - Removing electrical box
 - Removing High pressure switch and pressure switch for control
 - Opening electrical box (P-Mounting Plate)
 - Removing reversing and solenoid valves coils
 - Removing electronic expansion valve coil
 - Removing reversing valve
 - Removing Electronic expansion Valve and Solenoid Valve
 - Removing electrical components
 - Removing other electrical components
 
 
 - Outdoor Units RAS-(4-6)H(V)NCE
 - Inverter
 - Thermistor
 - Electronic expansion valve
 - High pressure protection device
 - Noise filter (NF)
 - Capacitor (CB1 CB2)
 - Reactor (DCL)
 - Scroll compressor
 - General notes
- Checking the power source and the wiring connection
 - Burnt-out compressor due to an insufficient refrigerant charge
 - Insufficient cooling performance when a long piping is applied
 - Abnormally high operation sound (in the ceiling type indoor unit).
 - Alarm code “31”
 - Not cooling well due to insufficient installation space for the outdoor unit
 
 - Maintenance work
 - Service and maintenance record
 - Service and maintenance record using the 7-segment display
 - Service and maintenance record by remote control switch
 - Pump-down method for replacing the compressor
 