Instruction Manual
Table Of Contents
- 1 Safety summary
- 2 Switch Names and Functions
- 3 Operation
- 4 Icon Description
- 5 Function Menu
- 5.1 Simple Timer Setting
- 5.2 Operation Schedule Setting
- 5.3 Power Savings Setting
- 5.4 Night Quiet Operation
- 5.5 Power Saving/Night Quiet Schedule Setting
- 5.6 Power Consumption Display
- 5.7 Autoboost (QUICK MODE) Setting
- 5.8 Comfort Setting
- 5.9 Motion sensor setting
- 5.10 Setback Setting
- 5.11 Elevating Grille
- 5.12 Filter Reminder Reset Setting
- 5.13 FrostWash
- 5.14 Individual Louver Setting
- 5.15 Cancel Individual Louver Setting
- 5.16 Louver Open/Close
- 5.17 Ventilation
- 5.18 Total Heat Exchanger Setting
- 6 Service & installation menu
- 6.1 Installation menu
- 6.1.1 Test Run
- 6.1.2 Function selection
- 6.1.3 Thermistor Selection
- 6.1.4 Input / Output Setting
- 6.1.5 Thermistor Calibration in Controller
- 6.1.6 Fan Speed at Cooling Thermo-OFF
- 6.1.7 Fan Speed at Heating Thermo-OFF
- 6.1.8 Indoor Unit Address Change
- 6.1.9 Address Check Operation
- 6.1.10 Address Initialization
- 6.1.11 Setting Initialization
- 6.1.12 Main Remote Setting
- 6.1.13 Priority Setting
- 6.1.14 Cancel Preheating Control
- 6.1.15 Elevating grille Setting
- 6.1.16 Power Up Setting
- 6.1.17 Setback Trigger Unit
- 6.1.18 Refrigerant Leak Sensor Setting
- 6.2 Service menu
- 6.3 Check Menu
- 6.1 Installation menu
- 7 Screen Display Setting menu
- 8 Contact Information menu
- 9 Hotel Mode Setting
- 10 In Alarm Condition
3 Select “Yes” and press “OK” to conrm the conguration.
4 When “Cancel” is selected, the screen returns to the
“Elevating Grille Setting” menu.
6.1.16 Power Up Setting
This function is used to set the maximum compressor frequency
and the target compressor frequency higher than usual. Power
up operation is performed after starting operation in the selected
operation mode (COOL only - HEAT ONLY - COOL+HEAT). This
function is available only for the compatible H-LINK 2 outdoor
units.
Please check the relevant technical information of the unit in
order to know if is compatible for this function.
1 Select “Power Up Setting”on the “Installation Menu” screen
and press “OK”.
2 If “
” or “ ” is pressed, the settings are selected in the
following order: “OFF” ↔ “COOL” ↔ “HEAT” ↔ “Cool +
Heat” Select the setting and press “OK” to conrm the
setting.
3 Press “ ” to return to the Installation Menu.
6.1.17 Setback Trigger Unit
The setback trigger unit can be set from the Installation Menu.
1 Select the indoor unit by pressing “
”, “ ”, “ ”, or “ ” and
press “OK” to display the conrmation screen.
2 Select “Yes” and press “OK” to conrm the setting. Then,
please wait a moment until the screen shows “Completed” or
“Setting Disabled”.
If “Cancel” is selected, the screen returns to the Setback
Trigger Unit screen.
EN
SERVICE & INSTALLATION MENU
PMML0565 rev.1 - 04/202269