10 IN ALARM CONDITION
When more than one indoor unit
is connected, press " " or " " to
show other indoor units.
Indoor unit number
(Refrigerant system-address number)
Installed unit number
The RUN indicator ashes.
The indoor unit number, alarm code, model code, and the connected number of indoor units are displayed on the screen.
If two or more indoor units are connected, the above functions for each indoor unit are displayed one-by-one.
10.1 POWER FAILURE
All the indicators are OFF.
Once the air conditioner is stopped by power failure for longer than 2 seconds, the air conditioner is not started again, although
power recovers. Perform the starting procedures again.
If the power recovers within 2 seconds, the air conditioner starts again automatically.
10.2 ELECTROMAGNETIC INTERFERENCE (EMI)
There could be an instance where all the indications are OFF and the unit is stopped.
This can occur through activation of the microcomputer for the air conditioner protection from the Electromagnetic Interference
(EMI).
Perform the starting procedures again.
EN
IN ALARM CONDITION