User's Manual
Auto electronic shutter (AES)
This function adjusts the light amount using only the CCD
shutter. Use this function with a fixed iris lens.
1) Press the SET button for longer than 2 seconds to display
the “MAIN MENU”.
2) Use the UP and DOWN buttons to shift the cursor to
“SHUTTER SPEED” ; the shutter speed setting flashes.
3) Press the SET button to select the speed sequentially in the
following order.
SET button:
OFF(1/60)→1/100→1/250→1/500→1/1000→1/2000→AES
The factory setting is OFF (1/60 second).
Shutter Speed setting
NOTE
1) lf using a DC type lens, fix the iris at fully open.
2) The AES function cannot be set with a video signal
type lens.
3) In the following types of cases, use a different shutter
speed. Strong light enters the scene, such as from a
spotlight or window.
・Strong smear or blooming occurs in the scene.
・Screen flicker or coloration occurs.
MAIN MENU
◆◆ MAIN MENU ◆◆
>CAMERA TITLE :OFF ↵
LIGHT CONTROL:OFF ↵
AGC :ON
↵
SHUTTER SPEED:OFF
SENS UP :OFF
B/W MODE :OFF
WHITE BALANCE:ATW
↵
SUB MENU
↵
END
…… Camera title setting menu
…… Light control setting menu
…… AGC setting menu
…… Shutter speed setting
…… Sensitivity enhance Setting
…… B/W mode setting (*)
…… White balance mode setting menu (*)
…… Sub menu
…… End of menu display
(*) Note: KP-E500 is not displayed.
Notes when AGC gain is set
Please note that there is a limitation in operation of using together with the function to show in the following when the amplification level
is set to 251 or more.
1) Shutter speed setting
When 251 or more sets the amplification level, the shutter speed can set only turning OFF, 1/100, and AES.
Please use by 250 or less by 1/125 – 1/2000 the shutter speed setting the amplification level to use it.
2) SENS UP setting
When 251 or more sets the amplification level, the SENS UP cannot be set. It becomes turning off fixation.
Please use by 250 or less by AUTO, MANUAL the SENS UP setting the amplification level to use it.
SHUTTER SPEED setting
OFF 1/100 From 1/125 to 1/2000 AES
250 or less
○ ○ ○ ○
FIX. GAIN
AGC LIMIT
251 or more
○ ○ ×(→OFF) ○
○: possible, ×: not possible
SENS UPsetting
OFF AUTO MANUAL
250 or less
○ ○ ○
FIX. GAIN
AGC LIMIT
251 or more
○ ×(→OFF) ×(→OFF)
○: possible, ×: not possible