Flat Panel Television User Manual
- 8 -
LCD TV Service Manual 
Hisense Confidential 
equipment and the high voltage power supply block, it can result in electric shock or 
activation of the leakage-detection circuit breaker. 
• When installing the LCD module in, and removing it from the packing carton, be sure 
to have at least two persons perform the work. 
• When the surface of the panel comes into contact with the cushioning materials, be 
sure to confirm that there is no foreign matter on top of the cushioning materials before 
the surface of the panel comes into contact with the cushioning materials. Failure to 
observe this precaution may result in, the surface of the panel being scratched by foreign 
matter. 
• When handling the circuit board, be sure to remove static electricity from your body 
before handling the circuit board. 
• Be sure to handle the circuit board by holding the large parts as the heat sink or 
transformer. Failure to observe this precaution may result in the occurrence of an 
abnormality in the soldered areas. 
• Do not stack the circuit boards. Failure to observe this precaution may result in 
problems resulting from scratches on the parts, the deformation of parts, and 
short-circuits due to residual electric charge. 
• Routing of the wires and fixing them in position must be done in accordance with the 
original routing and fixing configuration when servicing is completed. All the wires are 
routed far away from the areas that become hot (such as the heat sink). These wires are 
fixed in position with the wire clamps so that the wires do not move, thereby ensuring 