User Manual

2 phase conductors, 2 neutral conductor (220-240V 2 2N ~
/50/60Hz):
Voltage between lines and neutral conductor is 220–240V~.
The circuit should be fitted with at least two fuses of at least
16A each. Power cord core cross-sectional area should be at
least 1.5mm
2
.
Appliances with a width of 30 centimetres (two cooking zones)
only allow single-phase connection. The cross-sectional area of
the power cord core should be at least 1.5mm
2
.
CONNECTING THE POWER CORD
(appliance witha power cord)
The appliance has to be hard-wired directly to the power mains.
Devices for disconnecting from the power mains have to comply with the relevant
regulations.
Do not extend the power cord and do not lead it over sharp edges.
If the appliance is installed above an oven, make sure the power cord is never in contact
with the oven's hot parts.
Single-phase connection
Connect the appliance as shown in Diagram A. If your power mains do not allow a 32A
fuse, the appliance power should be decreased or limited accordingly.
See chapter SETTING THE MAXIMUM TOTAL APPLIANCE POWER.
L = brown
N = blue
= yellow-green
A
45
785435