User Manual Installation Industrial Ethernet Rail Switch SPIDER Standard Line Installation SPIDER-SL Release 05 08/2016 Technical support https://hirschmann-support.belden.eu.
The naming of copyrighted trademarks in this manual, even when not specially indicated, should not be taken to mean that these names may be considered as free in the sense of the trademark and tradename protection law and hence that they may be freely used by anyone. © 2016 Hirschmann Automation and Control GmbH Manuals and software are protected by copyright. All rights reserved.
Contents Safety instructions 5 About this Manual 10 Legend 10 1 Description 11 1.1 General device description 11 1.2 Device name and product code 11 1.3 Device view 1.3.1 Front view 13 13 1.4 Power supply 15 1.5 Ethernet ports 1.5.1 10/100/1000 Mbit/s twisted pair port 1.5.2 10/100 Mbit/s twisted pair port 1.5.3 100/1000 Mbit/s F/O port 1.5.4 100 Mbit/s F/O port 15 15 15 16 16 1.6 Pin assignments 16 1.7 Display elements 1.7.1 Device state 1.7.
5 Disassembly 27 5.1 Removing an SFP transceiver (optional) 27 5.
Safety instructions General safety instructions You operate this device with electricity. Improper usage of the device entails the risk of physical injury or significant property damage. The proper and safe operation of this device depends on proper handling during transportation, proper storage and installation, and careful operation and maintenance procedures. Before connecting any cable, read this document, and the safety instructions and warnings.
Qualification requirements for personnel Only allow qualified personnel to work on the device. Qualified personnel have the following characteristics: Qualified personnel are properly trained. Training as well as practical knowledge and experience make up their qualifications. This is the prerequisite for grounding and labeling circuits, devices, and systems in accordance with current standards in safety technology. Qualified personnel are aware of the dangers that exist in their work.
Requirements for connecting electrical wires Before connecting the electrical wires, always verify that the requirements listed are complied with. General requirements for connecting electrical wires The following requirements apply without restrictions: The electrical wires are voltage-free. The cables used are permitted for the temperature range of the application case. The voltage connected complies with the requirements for a safety extra-low voltage (SELV) as per IEC/EN 60950-1.
CE marking The labeled devices comply with the regulations contained in the following European directive(s): 2011/65/EU (RoHS) Directive of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronic equipment. 2014/30/EU (EMC) Directive of the European Parliament and the council for standardizing the regulations of member states with regard to electromagnetic compatibility.
FCC note: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference; (2) this device must accept any interference received, including interference that may cause undesired operation. Appropriate testing has established that this device fulfills the requirements of a class A digital device in line with part 15 of the FCC regulations.
About this Manual The “Installation User Manual” document contains a device description, safety instructions, a display description and further information that you require to install the device.
1 Description 1.1 General device description The SPIDER-SL devices are designed for the special requirements of industrial automation. They meet the relevant industry standards, provide very high operational reliability, even under extreme conditions, and also long-term reliability and flexibility. You have numerous options of combining the device characteristics. You can determine the possible combinations using the configurator which is available in the Belden E-Catalog (www.e-catalog.beldensolutions.
Item Characteristic 22 ...
1.3 Device view 1.3.1 Front view 1 1 2 1 1 2 2 2 3 3 3 11 3 10 4 9 5 8 6 11 10 4 9 5 8 7 7 SPIDER-SL-20-08T1... 4 6 5 6 SPIDER-SL-20-06T1... 7 4 8 5 SPIDER-SL-20-04T1... SPIDER-SL-20-01T1... Front view using example of device variants SPIDER-SL-20... SPIDER-SL-20-08T1... 1 LED display elements for device status 2 3-pin, pluggable terminal block for power supply 3 ... 6 4 × RJ45 socket for 10/100 Mbit/s twisted pair connections 7 Rail lock gate for DIN rail mounting 8 ...
1 1 2 1 1 2 2 3 3 4 4 2 3 11 3 10 4 11 9 5 10 6 9 5 6 8 6 9 7 8 6 7 SPIDER-SL-40-08T1... 12 5 11 4 10 5 8 7 SPIDER-SL-40-06T1... 8 7 SPIDER-SL-40-05T1... SPIDER-SL-40-06T1... Front view using example of device variants SPIDER-SL-40... SPIDER-SL-40-08T1... 1 LED display elements for device status 2 3-pin, pluggable terminal block for power supply 3 ... 6 4 × RJ45 socket for 10/100/1000 Mbit/s Twisted Pair connections 7 Rail lock gate for DIN rail mounting 8 ...
1.4 Power supply You have the following options to supply your device with voltage: Power supply via a 3-pin terminal block For the power supply of the device, a 3-pin terminal block is available. For further information see “Wiring the terminal block for the supply voltage and the grounding” on page 23. 1.5 Ethernet ports You can connect end devices and other segments to the device ports using twisted pair cables or optical fibers (F/O).
1.5.3 100/1000 Mbit/s F/O port This port is an SFP slot. The 100/1000 Mbit/s F/O port offers you the ability to connect network components according to the IEEE 802.3 100BASE-FX/1000BASESX/1000BASE-LX standard. This port supports: 100 Mbit/s full duplex when using a Fast Ethernet SFP transceiver 1000 Mbit/s full duplex when using a Gigabit Ethernet SFP transceiver 1.5.4 100 Mbit/s F/O port The 100 Mbit/s F/O port offers you the ability to connect network components according to the IEEE 802.
1.7 Display elements After the supply voltage is switched on, the device performs a self-test. During this process, various LEDs light up. 1.7.1 Device state This LED provides information on the status of the power supply.
1.7.2 Port state These LEDs provide port-related information.
2 Installation The devices have been developed for practical application in a harsh industrial environment. On delivery, the device is ready for operation. To configure a subdomain, follow these steps: Checking the package contents Mounting the device Installing an SFP transceiver (optional) Wiring the terminal block for the supply voltage and the grounding Operating the device Connecting data cables 2.
2.2 Mounting the device You have the following options for mounting your device: Installing the device onto the DIN rail Mounting on a flat surface 2.2.1 Installing the device onto the DIN rail Prerequisite: The device is for mounting on a 35 mm DIN rail in accordance with DIN EN 60715. 1 2 Proceed as follows: Slide the upper snap-in guide of the device into the DIN rail. Use a screwdriver to pull the rail lock gate downwards. Snap in the device by releasing the rail lock slide.
2.2.2 Mounting on a flat surface mm inch 57,5 2.26 42 1.65 52,7 2.07 35 1.38 35 1.38 O 6 0. ,5 26 25 1 20 0.8 O 5 6, 26 0. 24,25 0.95 35,75 1.41 mm inch 72 2.83 35 1.38 O 6 0. ,5 26 87,5 3.44 52,7 2.07 35 1.38 25 1 20 0.8 O 5 6, 26 0. 54,25 2.14 65,75 2.59 Proceed as follows: Attach the wall mounting plate to a flat surface of the wall using screws. You will find the dimensions necessary for mounting the device in the illustration. Mount the device on the wall mounting plate.
2.3 Installing an SFP transceiver (optional) Prerequisite: Use only Hirschmann SFP transceivers which are suitable for usage with the device. See “Accessories” on page 32. Proceed as follows: Remove the protection cap from the SFP transceiver. Push the transceiver with the lock closed into the slot until it latches in.
2.4 Wiring the terminal block for the supply voltage and the grounding WARNING ELECTRIC SHOCK Connect only a supply voltage that corresponds to the type plate of your device. Never insert sharp objects (small screwdrivers, wires, etc.) into the connection terminals for the supply voltage, and do not touch the terminals. Failure to follow these instructions can result in death, serious injury, or equipment damage. A 3-pin terminal block is used for the grounding and for connecting the supply voltage.
Proceed as follows: Ensure the required conditions for connecting the supply voltage. See “Requirements for connecting electrical wires” on page 7. Pull the terminal block off the device. Connect the ground connection. Connect the power supply cables. Plug the terminal block into the connection on the housing. 2.5 Operating the device By connecting the supply voltage via the terminal block, you start the operation of the device. 2.
3 Monitoring the ambient air temperature Operate the device below the specified maximum ambient air temperature exclusively. See “General technical data” on page 28. The ambient air temperature is the temperature of the air at a distance of 2 in (5 cm) from the device. It depends on the installation conditions of the device, e.g. the distance from other devices or other objects, and the output of neighboring devices.
4 Maintenance and service When designing this device, Hirschmann largely avoided using high-wear parts. The parts subject to wear and tear are dimensioned to last longer than the lifetime of the product when it is operated normally. Operate this device according to the specifications. Depending on the degree of pollution in the operating environment, check at regular intervals that the ventilation slots in the device are not obstructed.
5 Disassembly 5.1 Removing an SFP transceiver (optional) 2 1 Proceed as follows: Pull the SFP transceiver out of the slot by means of the opened lock. Close the SFP transceiver with the protective cap. 5.2 Removing the device 2 1 Proceed as follows: Disconnect the data cables. Disable the supply voltage. Remove the power connector from the device. Use a screwdriver to pull the rail lock gate downwards. Pull the device downwards from the DIN rail module.
6 Technical data General technical data Dimensions W×H×D Power supply Potential difference between input voltage and ground connection Climatic conditions during operation Climatic conditions during storage Pollution degree SPIDER Standard Line See “Dimension drawings” on page 29. 1 voltage input 3-pin terminal block Safety extra-low voltage (SELV) Rated voltage range DC 12 V ... 24 V Class 2 Voltage range DC incl. maximum 9.6 V ... 32 V tolerances Power loss buffer 10 ms at 20.
Dimension drawings 14,3 0.6 14,3 0.6 13,8 0.5 45 1.8 25,5 1 37,8 1.5 SPIDER-SL-20-06T1... 25,5 1 SPIDER-SL-20-01T1... SPIDER-SL-20-04T1... 102 4 110 4.3 SPIDER-SL-20-08T1... mm inch 14,3 0.6 82 3.2 6 0.2 73 2.9 6 0.2 Figure 2: Dimensions of device variants SPIDER-SL-20... 13,8 0.5 13,8 0.5 14,3 0.6 45 1.8 45 1.8 SPIDER-SL-40-06T1... 25,5 1 37,8 1.5 SPIDER-SL-40-05T1... SPIDER-SL-40-08T1... 110 4.3 102 4 SPIDER-SL-40-06T1... mm inch 14,3 0.6 82 3.2 6 0.2 73 2.9 6 0.
EMC and immunity EMC interference emission Radiated emission FCC 47 CFR Part 15 EN 55022 Conducted emission FCC 47 CFR Part 15 EN 55022 Class A Class A Class A Class A EMC interference immunity Electrostatic discharge EN 61000-4-2 Contact discharge IEEE C37.90.3 EN 61000-4-2 Air discharge IEEE C37.90.3 Electromagnetic field EN 61000-4-3 80 MHz ... 1000 MHz Fast transients (burst) EN 61000-4-4 DC supply connection IEEE C37.90.1 EN 61000-4-4 Data line IEEE C37.90.
Power consumption/power output at 24 V DC Device name SPIDER-SL-20-01T1... SPIDER-SL-20-04T1... SPIDER-SL-20-05T1... SPIDER-SL-20-06T1.....9... SPIDER-SL-20-06T1.....2... SPIDER-SL-20-08T1... SPIDER-SL-40-05T1... SPIDER-SL-40-06T1....99... SPIDER-SL-40-06T1....O6... SPIDER-SL-40-08T1... Max. power consumption 2.0 W 2.4 W 1.3 W 2.8 W 3.8 W 1.5 W 4.0 W 8.7 W 13.3 W 5.0 W Power output 7.0 BTU(IT)/h 8.3 BTU(IT)/h 4.6 BTU(IT)/h 9.5 BTU(IT)/h 12.8 BTU(IT)/h 5.3 BTU(IT)/h 13.7 BTU(IT)/h 29.6 BTU(IT)/h 45.
Accessories Note that products recommended as accessories may have different characteristics to those of the device, which may limit the application range of the overall system. For example, if you add an accessory with IP 20 to a device with IP 65, the IP of the overall system is reduced to 20. Other accessories 3-pin Low Voltage Interlock terminal block (50 pcs.) Rail Power Supply RPS 30 Rail Power Supply RPS 80 EEC Rail Power Supply RPS 120 EEC (CC) Wall mounting plate for DIN rail mounting, width 1.
Gigabit Ethernet SFP transceiver M-SFP-TX/RJ45 M-SFP-SX/LC M-SFP-SX/LC EEC M-SFP-MX/LC EEC M-SFP-LX/LC M-SFP-LX/LC EEC M-SFP-LX+/LC M-SFP-LX+/ LC EEC M-SFP-LH/LC M-SFP-LH/LC EEC M-SFP-LH+/LC SFP-GIG-LX/LCa SFP-GIG-LX/LC EECa Order number 943 977-001 943 014-001 943 896-001 942 108-001 943 015-001 943 897-001 942 023-001 942 024-001 943 042-001 943 898-001 943 049-001 942 196-001 942 196-002 a. You will find further information on the certificates on the Internet on the Hirschmann product pages (www.
A Further Support Technical Questions For technical questions, please contact any Hirschmann dealer in your area or Hirschmann directly. You will find the addresses of our partners on the Internet at http://www.hirschmann.com. A list of local telephone numbers and email addresses for technical support directly from Hirschmann is available at https://hirschmann-support.belden.eu.com. This site also includes a free of charge knowledge base and a software download section.
Installation SPIDER-SL Release 05 08/2016 35