User's Manual

Table Of Contents
Installation BAT-F
Release
18
07/2020
65
10.2 Dimension drawings
Figure 2: Dimensions of device variants and distance between suspensions.
Climatic
conditions during
storage
Minimum clearance around the
device
Top and bottom device side: 3.94 in
(10 cm)
Left and right device side: 0.79 in (2 cm)
Ambient air temperature
a
-40 °F ... +185 °F (-40 °C ... +85 °C)
Humidity 10 % ... 95 %
Air pressure min. 700 hPa (+9842 ft; +3000 m)
max. 1060 hPa (-1312 ft; -400 m)
Signal contact
“FAULT”
Switching current max. 1 A, SELV
Switching voltage Supply voltage with characteristic value C
(24 V DC ... 48 V DC) and K (60 V DC ...
250 V DC / 110 V AC ... 230 V AC,
50 Hz ... 60 Hz):
max. 60 V DC or max. 30 V AC, SELV
Supply voltage with the characteristic
value W:
max. 30 V DC, SELV
Pollution degree 2
Protection
classes
Laser protection Class 1 in compliance with IEC 60825-1
Degree of protection IP65/67
a. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
b. Use SFP transceivers with the “EEC” extension only, otherwise the standard temperature
range applies.
73
184
31 1
207
2
19
mm
in
12.24
7.24
8.15
8.62
2.87