User's Manual

Table Of Contents
64
Installation BAT-F
Release
18
07/2020
Supply voltage
with the
characteristic
value K
Power supply solely through a 7/8" connector
Rated voltage range AC: 110 V AC ... 230 V AC, 50 Hz ... 60 Hz
Voltage range including
maximum tolerances
88 V AC ... 265 V AC, 47 Hz ... 63 Hz
Rated voltage range 60 V DC ... 250 V DC
Voltage range incl. maximum
tolerances
48 V DC ... 320 V DC
Connection type 3-pin, 7/8" connector
Tightening
torque of the
locking screw
22 lb-in (2.5 Nm)
Power loss buffer >10 ms at 98 V AC
Overload current protection on
the device
Non-replaceable fuse
Back-up fuse for each voltage
input
Nominal rating:
Characteristic:
2.5 A
slow blow
Peak inrush current 14 A
Supply voltage
with the
characteristic
value P
Power supply exclusively via PoE
Supply voltage
with the
characteristic
value W
Power supply through a 7/8" connector
Rated voltage 24 V DC
Class 2
Voltage range incl. maximum
tolerances
16.8 V DC ... 32 V DC
Connection type 4-pin, 7/8" connector
Tightening
torque of the
locking screw
22 lb-in (2.5 Nm)
Power loss buffer >10 ms at 20.4 V DC
Overload current protection on
the device
Non-replaceable fuse
Back-up fuse Nominal rating:
Characteristic:
Max. 6.3 A
slow blow
Peak inrush current 14 A
Climatic
conditions during
operation
Ambient air temperature
a
Devices with operating temperature
characteristic value S (Standard):
+32 °F ... +140 °F (0 °C ... +60 °C)
Devices with operating temperature
characteristic value E and T (extended):
-40 °F ... +158 °F (-40 °C ... +70 °C)
b
Devices with operating temperature
characteristic value K (Extended with
Conformal Coating, approvals 1 with the
characteristic value K):
-40 °F ... +131 °F (-40 °C ... +55 °C)
Humidity 10 % ... 95 %
Air pressure up to 6562 ft (2000 m; 795 hPa), higher
altitudes upon request
max. 1060 hPa (-1312 ft; -400 m)