Installation BAT-F
Release
18
07/2020
Requirements for the fastening components:
The diameter of the mounting hardware is maximum 0.20 in (5 mm).
The head diameter is maximum 0.47 in (12 mm).
The diameter of a flat washer used is maximum 0.48 in (12 mm).
Prepare the assembly at the installation site.
See “Dimension drawings” on page 65.
Install the device with suitable fastening components.
Seal all unused connections and ports with protection screws.
See “Accessories” on page 82.
2.2.2 Installing the device on a pole
You have the option of installing the device on a pole, pipe, strut, or on a
similarly stable construction using a pole mounting set.
The pole mounting set you obtain as an accessory.
See “Accessories” on page 82.
The clamping diameter of the mast clamp is maximum 2.56 in (65 mm).
Tightening straps, available from a specialist dealer, enable you to clamp
a larger mast diameter.
maximum width of the tightening strap: 0.63 in (16 mm)
maximum thickness of the tightening strap: 0.05 in (1.3 mm)
2.2.3 Grounding the device
The device is grounded via the separate ground screw.
Terminate the ground conductor between the fastening plates.
Make sure the fastening plates cover the stripped part of the ground
conductor completely.
Tightening the ground screw.