User's Manual

Table Of Contents
Installation BAT-F
Release
18
07/2020
41
Note: With the point-to-point WLAN line, the following pins are short-circuited
at both ends:
2 (DTR) + 6 (DSR)
7 (RTS) + 8 (DSR)
1.8.2 USB interface
This interface offers you the ability to connect the storage medium
AutoConfiguration Adapter ACA21-M12 (EEC) / ACA22-M12 (EEC). This
storage medium is used for saving/loading the configuration and diagnostic
functions, and for loading the software.
This interface is a 5-pin, “A”-coded M12 socket with shielding.
Note: The AutoConfiguration adapter ACA11-M12 available for certain
Hirschmann devices is incompatible with BAT-F devices.
1.9 Signal contact
Only device variants featuring supply voltage with characteristic value C
(24 V DC ... 48 V DC), K (60 V DC ... 250 V DC / 110 V AC ... 230 V AC,
50 Hz ... 60 Hz) or W (24 V DC) have a signal contact.
You have the option of setting the signal contact manually using the device
management.
Further information:
“Signal contact” on page 49
1.10 Reset button
The device has a reset button.
Pin Function
1U
in
5 V
2 N.C. Not used
3D-Data -
4 GND Ground (0 V)
5D+Data +