1.8 Management interfaces
1.8.1 V.24 interface (external management)
This interface is designed as an 8-pin, “A”-coded M12 plug.
The V.24 user interface is serial and allows you to connect the following
devices directly:
External management station (VT100 terminal or PC with appropriate
terminal emulation). With this management station, the Command Line
Interface (CLI) is available to you. Furthermore, the system monitor is
available to you at the system start.
You will find more information here:
table 5 on page 40
BAT-F device. Connecting the BAT-F device allows you to automate the
configuration of a point-to-point WLAN line by connecting two devices
directly via the serial interface.
You will find more information here:
User Manual Configuration Guide
The manual is available for download on the Internet: https://
www.doc.hirschmann.com
table 6 on page 40
The socket housing is electrically connected to the device casing. The V.24
interface is electrically insulated from the supply voltage.
Only use a shielded cable.
green glowing Ethernet connection active
yellow flickering Data traffic
VT100 terminal settings
Speed 115200 bit/s
Data 8 bit
Stopbit 1 bit
Handshake Hardware
Parity none
ETH1, ETH2 (green/yellow LED) Meaning