Datasheet
198
HR10 Series●Push-Pull Connectors
■Recommended Mounting Hole
Mounting hole dimension shown here is tight by hexagon nut from back side.
■Precautions
1. Switch off the power of the circuit before disconnecting or plugging-in the connector.
2. Use a connector with socket contacts at the power side of the circuit.
3. Make sure that the coupling is in completely cocked position.
4. The cable pull and twisting strength and other characteristics may differ, deponding on the cable structure.
Please confirm vefore the use.
7 size 10 size 13 size
A 1.6 2.6 2.6
B 5.1 6.6 8.6
C 8.1 11.1 14.5
Panel thickness 0.7~2 0.7~2 0.8~1.5
Shell size
Map mark
+0.1
0
+0.1
0
+0.1
0
+0.1
0
+0.1
0
+0.1
0
+0.1
0
+0.1
0
+0.1
0
■Contact arrangement
Shell size 7 size 10 size
Contact arrangement
No. of pins 4 5 6 10 12
Withstanding voltage AC500V for a minute AC300V for a minute AC300V for a minute
Current rating 2A 2A 2A
Insulation resistance MIN 1,000Mø MIN 1,000Mø MIN 1,000Mø
Contact resistance MAX 10mø MAX 10mø MAX 10mø
Solder pot inside dia. Ø0.8 Ø0.8 Ø0.8
Shell size 10 size
13 size
Contact arrangement
No. of pins 10+coaxial contact 20
Withstanding voltage AC300V for a minute AC300V for a minute
Current rating 2A 2A
Insulation resistance MIN 1,000Mø MIN 1,000Mø
Contact resistance MAX 10mø MAX 10mø
Solder pot inside dia. - Ø0.8
Note 1. The contact arrangement shown here is the mating surface of socket insert assembled in a receptacle.
2. The withstanding voltage shown here is test voltage value.
3. The isulation resistance value is measured at DC100V.
4. The contact resistance value is measured at DC1A.
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.